The DOI matches its Crossref record.
Metallocenes as references for the determination of redox potentials by cyclic voltammetry Permethylated iron and cobalt sandwich complexes, inhibition by polyamine dendrimers, and the role of hydroxy-containing ferrocenes
Abstract
Measurement of the redox potentials (E 1/2) of ferrocene (1), decamethylferrocene (2), decamethylcobaltocene (3), and [Fe I Cp*(η 6-C 6 Me 6)] (4) (Cp* = η 5-C 5 Me 5) in DMF, CH 3 CN, THF, DME, CH 2 Cl 2, and DMSO were recorded vs. the saturated calomel electrode (SCE), showing that the E 1/2 value of 1 was more solvent dependent than those of 24, and that the difference in E 1/2 values among 24 was solvent independent, unlike those found between 1 and 24. This shows that 24 are much more reliable internal references for determining redox potentials than 1, but using data from this article, one can convert the literature values reported vs. 1 into values vs. 2, 3, or 4. The electrochemistry of 1 and 2 is all the more inhibited by polyamine dendrimers as the dendrimer generation is higher. On the other hand, ferrocenes or other iron sandwich compounds containing hydroxy groups can reestablish reversible cyclic voltammograms. It is shown, using a tetra(ferrocenylmethylamine), that this phenomenon is due to hydrogen bonding between the amido and phenol groups rather than bonding of hydroxy groups to the electrode surface.Key words: ferrocene, reference, electrochemistry, metallocene, sandwich complex, iron, dendrimer, passivation, hydrogen bond.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A practical beginner’s guide to cyclic voltammetry
Elgrishi, N., Rountree, K. J., McCarthy, B. D., Rountree, E. S., Eisenhart, T. T., & Dempsey, J. L. (2018) · Journal of Chemical Education · doi:10.1021/acs.jchemed.7b00361 · Cited by 4,263
Astruc, D., Boisselier, E., & Ornelas, C. (2010) · Chemical Reviews · doi:10.1021/cr900327d · Cited by 1,844
Self-citationWhy is Ferrocene so Exceptional?
Astruc, D. (2017) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.201600983 · Cited by 653
Self-citationMolecular polypyridine-based metal complexes as catalysts for the reduction of CO2
Elgrishi, N., Chambers, M. B., Wang, X., & Fontecave, M. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00391a · Cited by 555
Metadata
- Authors
- Aranzaes, J. R., Daniel, M.-C., & Astruc, D.
- Venue
- Canadian Journal of Chemistry
- Publisher
- Canadian Science Publishing
- Published
- 2006-02-01
- Volume
- 84
- Issue
- 2
- Pages
- 288-299
- ISSN
- 0008-4042 (ISSN-L)
- 1480-3291
- OpenAlex
- W2170909829
- Cited by
- 312
- References
- 0
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metallocenes as references for the determination of redox potentials by cyclic voltammetry Permethylated iron and cobalt sandwich complexes, inhibition by polyamine dendrimers, and the role of hydroxy-containing ferrocenes. https://app.cochat.ai/papers/10.1139/v05-262
- The paper
- Aranzaes, J. R., Daniel, M.-C., & Astruc, D. (2006). Metallocenes as references for the determination of redox potentials by cyclic voltammetry Permethylated iron and cobalt sandwich complexes, inhibition by polyamine dendrimers, and the role of hydroxy-containing ferrocenes. Canadian Journal of Chemistry. https://doi.org/10.1139/v05-262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.