Multi-Biosignal Analysis for Epileptic Seizure Monitoring
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Persons who suffer from intractable seizures are safer if attended when seizures strike. Consequently, there is a need for wearable devices capable of detecting both convulsive and nonconvulsive seizures in everyday life. We have developed a three-stage seizure detection methodology based on 339 h of data (26 seizures) collected from 10 patients in an epilepsy monitoring unit. Our intent is to develop a wearable system that will detect seizures, alert a caregiver and record the time of seizure in an electronic diary for the patient’s physician. Stage I looks for concurrent activity in heart rate, arterial oxygenation and electrodermal activity, all of which can be monitored by a wrist-worn device and which in combination produce a very low false positive rate. Stage II looks for a specific pattern created by these three biosignals. For the patients whose seizures cannot be detected by Stage II, Stage III detects seizures using limited-channel electroencephalogram (EEG) monitoring with at most three electrodes. Out of 10 patients, Stage I recognized all 11 seizures from seven patients, Stage II detected all 10 seizures from six patients and Stage III detected all of the seizures of two out of the three patients it analyzed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time-frequency mapping of R-R interval during complex partial seizures of temporal lobe origin.
Novak, V., Reeves, A. L., Novak, P., Low, P. A., & Sharbrough, F. W. (1999) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(99)00044-2 · Cited by 101
Using photoplethysmography in heart rate monitoring of patients with epilepsy
van Andel, J., Ungureanu, C., Aarts, R., Leijten, F., & Arends, J. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.02.018 · Cited by 39
Cited by
Automated EEG-based screening of depression using deep convolutional neural network
Acharya, U. R., Oh, S. L., Hagiwara, Y., Tan, J. H., Adeli, H., & Subha, D. P. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.012 · Cited by 650
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403
A Deep Learning Model for Automated Sleep Stages Classification Using PSG Signals
Yildirim, O., Baloglu, U. B., & Acharya, U. R. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16040599 · Cited by 263
Multicenter clinical assessment of improved wearable multimodal convulsive seizure detectors
Onorati, F., Regalia, G., Caborni, C., Migliorini, M., Bender, D., Poh, M., Frazier, C., Kovitch Thropp, E., Mynatt, E. D., Bidwell, J., et al. (2017) · Epilepsia · doi:10.1111/epi.13899 · Cited by 212
Acharya, U. R., Hagiwara, Y., & Adeli, H. (2018) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2018.09.030 · Cited by 207
DepHNN: A novel hybrid neural network for electroencephalogram (EEG)-based screening of depression
Sharma, G., Parashar, A., & Joshi, A. M. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102393 · Cited by 186
A hybrid deep neural network for classification of schizophrenia using EEG Data
Sun, J., Cao, R., Zhou, M., Hussain, W., Wang, B., Xue, J., & Xiang, J. (2021) · Scientific Reports · doi:10.1038/s41598-021-83350-6 · Cited by 169
Automatic seizure detection using three-dimensional CNN based on multi-channel EEG
Wei, X., Zhou, L., Chen, Z., Zhang, L., & Zhou, Y. (2018) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-018-0693-8 · Cited by 159
“There are numerous technological researches based on artificial features and machine learning classifiers [6].”
BackgroundVieluf, S., Amengual‐Gual, M., Zhang, B., El Atrache, R., Ufongene, C., Jackson, M. C., Branch, S., Reinsberger, C., & Loddenkemper, T. (2021) · Epilepsia · doi:10.1111/epi.16843 · Cited by 54
Böttcher, S., Bruno, E., Manyakov, N. V., Epitashvili, N., Claes, K., Glasstetter, M., Thorpe, S., Lees, S., Dümpelmann, M., Van Laerhoven, K., et al. (2021) · JMIR mHealth and uHealth · doi:10.2196/27674 · Cited by 39
“Although there have been some studies using ECG [20-23] or PPG [17,18,23,24] signals for epileptic seizure detection, the considerable movements during convulsive seizures frequently render this signal too noisy for accurate ictal heart rate determination.”
BackgroundMethodHubbard, I., Beniczky, S., & Ryvlin, P. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.740743 · Cited by 34
Böttcher, S., Bruno, E., Epitashvili, N., Dümpelmann, M., Zabler, N., Glasstetter, M., Ticcinelli, V., Thorpe, S., Lees, S., Van Laerhoven, K., et al. (2022) · Sensors · doi:10.3390/s22093318 · Cited by 23
“2017 [9] use a combination of two different wearable devices to record the biosignal modalities EDA, ECG, and SpO2, and report an algorithm sensitivity of 50% with a false alarm rate of 0.”
BackgroundMethodResultInfluential
Metadata
- Authors
- Cogan, D., Birjandtalab, J., Nourani, M., Harvey, J., & Nagaraddi, V.
- Venue
- International Journal of Neural Systems
- Publisher
- World Scientific Pub Co Pte Ltd
- Published
- 2016-11-08
- Volume
- 27
- Issue
- 01
- Pages
- 1650031
- ISSN
- 0129-0657 (ISSN-L)
- 1793-6462
- OpenAlex
- W2319851220
- Cited by
- 124
- References
- 2
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.