USER INDEPENDENT GESTURE INTERACTION FOR SMALL HANDHELD DEVICES
The DOI matches its Crossref record.
Abstract
Accelerometer-based gesture recognition facilitates a complementary interaction modality for controlling mobile devices and home appliances. Using gestures for the task of home appliance control requires use of the same device and gestures by different persons, i.e. user independent gesture recognition. The practical application in small embedded low-resource devices also requires high computational performance. The user independent gesture recognition accuracy was evaluated with a set of eight gestures and seven users, with a total of 1120 gestures in the dataset. Twenty-state continuous HMM yielded an average of 96.9% user independent recognition accuracy, which was cross-validated by leaving one user in turn out of the training set. Continuous and discrete five-state HMM computational performances were compared with a reference test in a PC environment, indicating that discrete HMM is 20% faster. Computational performance of discrete five-state HMM was evaluated in an embedded hardware environment with a 104 MHz ARM-9 processor and Symbian OS. The average recognition time per gesture calculated from 1120 gesture repetitions was 8.3 ms. With this result, the computational performance difference between the compared methods is considered insignificant in terms of practical application. Continuous HMM is hence recommended as a preferred method due to its better suitability for a continuous-valued signal, and better recognition accuracy. The results suggest that, according to both evaluation criteria, HMM is feasible for practical user independent gesture control applications in mobile low-resource embedded environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Activity Recognition from On-Body Sensors: Accuracy-Power Trade-Off by Dynamic Sensor Selection
Zappi, P., Lombriser, C., Stiefmeier, T., Farella, E., Roggen, D., Benini, L., & Tröster, G. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-77690-1_2 · Cited by 329
A benchmark dataset to evaluate sensor displacement in activity recognition
Baños, O., Damas, M., Pomares, H., Rojas, I., Tóth, M. A., & Amft, O. (2012) · Proceedings of the 2012 ACM Conference on Ubiquitous Computing · doi:10.1145/2370216.2370437 · Cited by 163
Activity recognition from on-body sensors by classifier fusion: sensor scalability and robustness
Zappi, P., Stiefmeier, T., Farella, E., Roggen, D., Benini, L., & Troster, G. (2007) · 2007 3rd International Conference on Intelligent Sensors, Sensor Networks and Information · doi:10.1109/issnip.2007.4496857 · Cited by 126
“The recognition of activities and gestures from body-worn sensors may be applied e.g. in human-computer interfaces [3], [4], sports [5], and also for context-aware support in automotive production [6], [7], [8].”
Background
Metadata
- Authors
- KALLIO, S., KELA, J., KORPIPÄÄ, P., & MÄNTYJÄRVI, J.
- Venue
- International Journal of Pattern Recognition and Artificial Intelligence
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2006-06
- Volume
- 20
- Issue
- 04
- Pages
- 505-524
- ISSN
- 0218-0014 (ISSN-L)
- 1793-6381
- OpenAlex
- W2120305318
- Cited by
- 42
- References
- 0
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: USER INDEPENDENT GESTURE INTERACTION FOR SMALL HANDHELD DEVICES. https://app.cochat.ai/papers/10.1142/s0218001406004776
- The paper
- KALLIO, S., KELA, J., KORPIPÄÄ, P., & MÄNTYJÄRVI, J. (2006). USER INDEPENDENT GESTURE INTERACTION FOR SMALL HANDHELD DEVICES. International Journal of Pattern Recognition and Artificial Intelligence. https://doi.org/10.1142/s0218001406004776
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.