Cited by 21Terahertz technology and applicationsSpectroscopy and Laser ApplicationsThermography and Photoacoustic Techniques

DIRECT FABRY-PÉROT EFFECT REMOVAL

WITHAYACHUMNANKUL, WITHAWAT, FERGUSON, BRADLEY, RAINSFORD, TAMATH, MICKAN, SAMUEL, ABBOTT, DEREK·2006·Fluctuation and Noise Letters

Abstract

This study indicates that the removal of reflections from T-ray signals can be carried out in the frequency domain without prior knowledge of material parameters or sample thickness. By fitting polynomials to the logarithm and the argument of the sample's transfer function, the Fabry-Pérot reflection term is canceled out, leading to disappearance of the reflections in spatial domain. The method successfully removes the reflections for optically thick samples under the condition of noise or amplitude fluctuations. The application to optically thin samples is possible when the samples are subjected to broadband terahertz measurements. The Fabry-Pérot free signal, when used as input to the parameter estimation method, results in correct material parameters with low variance.

Integrity signals

Registry

Crossref · 10.1142/s0219477506003318

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Increasing sample thickness decreases the variance in optical constants due to amplitude variance, but also lowers the sample signal amplitude and thus lifts the overall variance.

    “Increasing the thickness will seemingly decrease the variance in the optical constants.”

The citation lists haven’t been fetched yet

References 12 · Cited by 21

Authors
WITHAYACHUMNANKUL, W., FERGUSON, B., RAINSFORD, T., MICKAN, S., & ABBOTT, D.
Affiliations
The University of Adelaide (AU)
Venue
Fluctuation and Noise Letters
Published
2006-06
Volume
06
Issue
02
Pages
L227-L239
ISSN
  • 0219-4775 (ISSN-L)
  • 1793-6780
OpenAlex
W2087110487
Cited by
21
References
12
Citations by year
2025: 1 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 1 · 2015: 1
FWCI
2.36
Type
journal article
Language
en
Open access
closed
Locations
  • Fluctuation and Noise Letters (publishedVersion)
  • Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
Keywords
Fabry-Perot effect, reflection removal, terahertz transmission, frequency-domain signal processing, polynomial fitting, transfer function, material parameter identification

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review