DIRECT FABRY-PÉROT EFFECT REMOVAL
Abstract
This study indicates that the removal of reflections from T-ray signals can be carried out in the frequency domain without prior knowledge of material parameters or sample thickness. By fitting polynomials to the logarithm and the argument of the sample's transfer function, the Fabry-Pérot reflection term is canceled out, leading to disappearance of the reflections in spatial domain. The method successfully removes the reflections for optically thick samples under the condition of noise or amplitude fluctuations. The application to optically thin samples is possible when the samples are subjected to broadband terahertz measurements. The Fabry-Pérot free signal, when used as input to the parameter estimation method, results in correct material parameters with low variance.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Increasing sample thickness decreases the variance in optical constants due to amplitude variance, but also lowers the sample signal amplitude and thus lifts the overall variance.
“Increasing the thickness will seemingly decrease the variance in the optical constants.”
From Uncertainty in terahertz time-domain spectroscopy measurement (2008) · cites this paper as [20]
The citation lists haven’t been fetched yet
References 12 · Cited by 21
- Authors
- WITHAYACHUMNANKUL, W., FERGUSON, B., RAINSFORD, T., MICKAN, S., & ABBOTT, D.
- Affiliations
- The University of Adelaide (AU)
- Venue
- Fluctuation and Noise Letters
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2006-06
- Volume
- 06
- Issue
- 02
- Pages
- L227-L239
- ISSN
- 0219-4775 (ISSN-L)
- 1793-6780
- OpenAlex
- W2087110487
- Cited by
- 21
- References
- 12
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 1 · 2015: 1
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Fluctuation and Noise Letters (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Keywords
- Fabry-Perot effect, reflection removal, terahertz transmission, frequency-domain signal processing, polynomial fitting, transfer function, material parameter identification
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review