EFFECT OF CONDENSATION ON THE EFFICIENCY OF HEAT RECOVERY VENTILATORS FOR BROILER HOUSES
Abstract
This study experimentally investigates the effect of internal condensation on the performance of a heat recovery ventilator. Experiments were performed using a plate-type sensible heat exchanger element that was designed for very humid and dusty environments such as chicken broiler houses. The results of these experiments show that the temperature efficiency considering condensation is always greater than that without considering latent heat. As outdoor temperature decreases or indoor relative humidity increases, temperature efficiency increases owing to an increase in the rate of condensation. The present polypropylene-based sensible heat exchanger element could be a solution for harsh environments because it can discharge condensate water by gravity and is resistant to moisture and other toxic gases.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
CFD simulation shows reasonable agreement with experimental work [88].
“The CFD simulation shows reasonable agreement with the experimental work [88].”
Cited by
Sorted by citations
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
- Authors
- HAN, H., NAM, S.-H., & HAN, G.-S.
- Affiliations
- Kookmin University (KR)
- Graduate School of Engineering, Kookmin University, Seoul 136-702, Korea
- ORCID
- HAN, HWATAIK
- Venue
- International Journal of Air-Conditioning and Refrigeration
- Published
- 2013-06
- Volume
- 21
- Issue
- 02
- Pages
- 1350009
- ISSN
- 2010-1325 (ISSN-L)
- 2010-1333
- OpenAlex
- W2139412469
- Cited by
- 6
- References
- 0
- Citations by year
- 2021: 1 · 2016: 3 · 2015: 2
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Air-Conditioning and Refrigeration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- heat recovery ventilator, internal condensation, broiler houses, plate heat exchanger, temperature efficiency, latent heat, relative humidity, outdoor temperature, poultry house ventilation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review