Cited by 74Gold and Silver Nanoparticles Synthesis and ApplicationsSpectroscopy Techniques in Biomedical and Chemical ResearchSARS-CoV-2 detection and testing

Rapid ratiometric biomarker detection with topically applied SERS nanoparticles

Open access
Wang, Yu "Winston, Khan, Altaz, Som, Madhura, Wang, Danni, Chen, Ye, Leigh, Steven Y., Meza, Daphne, McVeigh, Patrick Z. +2 more·2014·TECHNOLOGY

Abstract

Multiplexed surface-enhanced Raman scattering (SERS) nanoparticles (NPs) offer the potential for rapid molecular phenotyping of tissues, thereby enabling accurate disease detection as well as patient stratification to guide personalized therapies or to monitor treatment outcomes. The clinical success of molecular diagnostics based on SERS NPs would be facilitated by the ability to accurately identify tissue biomarkers under time-constrained staining and detection conditions with a portable device. In vitro, ex vivo and in vivo experiments were performed to optimize the technology and protocols for the rapid detection (0.1-s integration time) of multiple cell-surface biomarkers with a miniature fiber-optic spectral-detection probe following a brief (5 min) topical application of SERS NPs on tissues. Furthermore, we demonstrate that the simultaneous detection and ratiometric quantification of targeted and nontargeted NPs allows for an unambiguous assessment of molecular expression that is insensitive to nonspecific variations in NP concentrations.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1142/s2339547814500125

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 53 · Cited by 74

Authors
Wang, Y. "., Khan, A., Som, M., Wang, D., Chen, Y., Leigh, S. Y., Meza, D., McVeigh, P. Z., Wilson, B. C., & Liu, J. T. C.
Affiliations
  • Stony Brook University (US)
  • University of Toronto (CA)
Venue
TECHNOLOGY
Published
2014-06
Volume
02
Issue
02
Pages
118-132
ISSN
  • 2339-5478 (ISSN-L)
  • 2345-7740
OpenAlex
W2030180978
Cited by
74
References
53
Citations by year
2025: 1 · 2024: 4 · 2023: 4 · 2022: 1 · 2021: 7 · 2020: 6 · 2019: 11 · 2018: 9 · 2017: 9 · 2016: 9 · 2015: 11 · 2014: 2
FWCI
3.49
Type
journal article
Language
en
Open access
Locations
  • TECHNOLOGY (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Stony Brook University
  • National Institutes of Health
  • National Institute of Biomedical Imaging and Bioengineering (R21EB015016)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
Keywords
ratiometric detection, tissue biomarkers, cell surface markers, portable detection device, molecular phenotyping, molecular diagnosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›