Thermal Conductivity Measurement of Molten Silicon by a Hot-Disk Method in Short-Duration Microgravity Environments
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The thermal conductivity of molten silicon was measured by a hot-disk method in short-duration microgravity environments. The hot-disk sensor was made of molybdenum foil cut in a conducting pattern and covered with an aluminum nitride plate. Aluminum nitride has good resistivity against corrosion from silicon melt and the molybdenum foil was protected from the molten silicon. The thermal conductivity of molten silicon measured on the ground was estimated to be 45.6 W·m-1·K-1 at the melting point (1687 K). The thermal conductivity of molten silicon measured in microgravity was about 5% lower than that measured on the ground.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although the literature [33] claims that TPS method has a wide temperature application range, specifically from 25 K to 1500 K, numerous studies and tests have been predominantly carried out at room temperature and high temperature conditions[14,15,29,34].”
From An improved platinum probe used for transient plane source method at cryogenic temperatures (2025) · cites this paper as [34]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gustafsson, S. E. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142087 · Cited by 1,691
Self-citationLog, T., & Gustafsson, S. E. (1995) · Fire and Materials · doi:10.1002/fam.810190107 · Cited by 357
Self-citation
Research works printed but not linked: 12
- 1985, High Temp.-High Press., 17, 699
- 1983, High Temp.-High Press., 15, 191
- 1981, Rev. Sci. Instrum., 52, 229, 10.1063/1.1136577 · DOI · Paper page
- 1990, Rev. Sci. Instrum., 61, 2645, 10.1063/1.1141853 · DOI
- 1991, Int. J. Thermophys., 12, 783, 10.1007/BF00502405 · doi:10.1007/bf00502405
- 1993, Microgravity Sci. Technol., 6, 119
- 1998, J. Jpn. Soc. Microgravity Appl., 15, 79
- 1991, Jpn. J. Appl. Phys., 30, 2423, 10.1143/JJAP.30.2423 · DOI
- 1969, 10.1007/978-1-4899-6451-9 · doi:10.1007/978-1-4899-6451-9
- 1956, Zh. Tekh. Fiz., 26, 1366
- 1995, Jpn. J. Appl. Phys., 34, 3426, 10.1143/JJAP.34.3426 · doi:10.1143/jjap.34.3426
- Mater. Sci. & Eng. A.
Cited by
An improved platinum probe used for transient plane source method at cryogenic temperatures
Zhao, P., & Wang, Q. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.126207 · Cited by 3
Metadata
- Authors
- Nagai, H., Nakata, Y., Tsurue, T., Minagawa, H., Kamada, K., Gustafsson, S. E., & Okutani, T.
- Venue
- Japanese Journal of Applied Physics
- Publisher
- IOP Publishing
- Published
- 2000-03-01
- Volume
- 39
- Issue
- 3R
- Pages
- 1405
- ISSN
- 0021-4922
- 1347-4065
- Cited by
- 30
- References
- 2
- Licence
- iopscience.iop.org/page/copyright (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.