The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
On the Effect of High Energy Radiation to Polymers I. Cross-linking and Degradation
Abstract
Integro-differential equations are obtained, which describe the variation of molecular weight distributions in a polymer substance caused by irradiation. The solutions of these equations give the gel point and the average molecular weights. In the case of cross-linking without cyclization, the results agree with those obtained by other authors. The problems involving cyclization and branching are also solved, showing that the gel formation is retarded by cyclization and that the weight average branching number diverges at the gel point, while the number average branching number does not. As for degradation, the molecular weight distributions for an arbitrary radiation dose are obtained, and it is shown that for any initial distribution the final molecular weight distribution becomes Poisson-like. The problem which deals with the case where cross-linking and degradation coexist is also discussed, and it is shown that for any initial distribution the gel formation occurs only when the ratio of the two probabilities concerning degradation and cross-linking is smaller than 4.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Calculations based on the above equations demonstrate that the change of molecular mass corresponding to chain scission in deformed samples is negligibly small: for the high strain e ¼ 2.1 the calculated ratio M n /M no ¼ 0.998 while M w /M wo ¼ 0.993.”
From Erosion of the molecular network in the amorphous layers of polyethylene upon high-strain deformation (2016) · cites this paper as [54]
Citations
Cites
Molecular Size Distribution in Three Dimensional Polymers. I. Gelation 1
Flory, P. J. (1941) · Journal of the American Chemical Society · doi:10.1021/ja01856a061 · Cited by 1,953
Theory of Molecular Size Distribution and Gel Formation in Branched-Chain Polymers
STOCKMAYER, W. H. (1943) · The Journal of Chemical Physics · doi:10.1063/1.1723803 · Cited by 1,919
STOCKMAYER, W. H. (1944) · The Journal of Chemical Physics · doi:10.1063/1.1723922 · Cited by 975
Molecular Size Distribution in Three Dimensional Polymers. II. Trifunctional Branching Units
Flory, P. J. (1941) · Journal of the American Chemical Society · doi:10.1021/ja01856a062 · Cited by 546
Molecular Size Distribution in Three Dimensional Polymers. III. Tetrafunctional Branching Units
Flory, P. J. (1941) · Journal of the American Chemical Society · doi:10.1021/ja01856a063 · Cited by 450
Constitution of Three-dimensional Polymers and the Theory of Gelation.
Flory, P. J. (1942) · The Journal of Physical Chemistry · doi:10.1021/j150415a016 · Cited by 244
Molecular-weight changes in the degradation of long-chain polymers
Charlesby, A. (1954) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1954.0145 · Cited by 192
Solubility and molecular size distribution of crosslinked polystyrene
Charlesby, A. (1953) · Journal of Polymer Science · doi:10.1002/pol.1953.120110601 · Cited by 160
Gel formation and molecular weight distribution in long-chain polymers
Charlesby, A. (1954) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1954.0094 · Cited by 131
The cross-linking and degradation of paraffin chains by high-energy radiation
Charlesby, A. (1954) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1954.0052 · Cited by 110
Research works printed but not linked: 4
- Charlesby A., 1954, Proc. Roy. Soc., 222, 60
- Charlesby A., 1954, Proc. Roy. Soc., 222, 542
- Charlesby A., 1954, Proc. Roy. Soc., 224, 120
- Charlesby A., 1955, Proc. Roy. Soc., 231, 521
Cited by
Sorted by citations
Items 201–235 of 235
Kotliar, A. M. (1962) · Journal of Polymer Science · doi:10.1002/pol.1962.1206217437 · Cited by 2
Theoretical considerations of scission and endlinking reactions in irradiated polymers
Babic, D., & Stannett, V. (1987) · International Journal of Radiation Applications and Instrumentation Part C Radiation Physics and Chemistry · doi:10.1016/1359-0197(87)90077-4 · Cited by 2
Durabilité de produits innovants de robinetterie en polyamide 6,6
Mazry, C. E. (2013) · doi:10.70675/4c4d84ddz006cz40afzbb5fzf9bb5dd6c398 · Cited by 2
Scuffing: Material Phenomena, Interfacial Effects, and Mitigating Practices
Delaney, B., Ellini, A., Kim, J., Zhang, M., Nazar, N., Daley, N., Gonzalez, D., Shilati, A., Batteas, L. C., Boris, E., et al. (2026) · Tribology Letters · doi:10.1007/s11249-026-02144-x · Cited by 1
Babic, D. (1989) · Makromolekulare Chemie Macromolecular Symposia · doi:10.1002/masy.19890280116 · Cited by 1
Benzarti, K., & Colin, X. A. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-820346-0.00024-1 · Cited by 1
Chappa, V. C., Pastorino, C., del Grosso, M. F., Arbeitman, C. R., Müller, M., & Bermúdez, G. G. (2010) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2010.05.097 · Cited by 1
Diffusion Processes in Polymers under Irradiation; Polyvinyl Alcohol and CCl 4 System
Watanabe, T. (1958) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.13.1316 · Cited by 1
Change of Molecular Size Distribution of Polymers Induced by Crosslinking. II. Poisson Distribution
Amemiya, A. (1967) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.23.1402 · Cited by 1
Isothermal EHL problem for chemically degrading lubricant
Kudish, I. I., & Airapetyan, R. G. (2002) · Tribology series · doi:10.1016/s0167-8922(02)80046-3
New Developments in the Field of Radiochemical Ageing of Aromatic Polymers
Richaud, E., Audouin, L., Colin, X. A., Bruno Fayolle, C., & Jacques Verdu, C. (2012) · InTech eBooks · doi:10.5772/34874
Aspects of electron resist exposure
Webb, D., & Hardy, C. J. (1977) · Vacuum · doi:10.1016/s0042-207x(77)80427-2
Colin, X. A., Audouin, L., & Jacques Verdu, C. (2009) · European Journal of Environmental and Civil engineering · doi:10.1080/19648189.2009.9693169
Alvarez, G. A., Cantow, H. ‐., & Hasenhindl, A. (1981) · Polymer Bulletin · doi:10.1007/bf00284070
Vokal, A. (1986) · International Journal of Radiation Applications and Instrumentation Part C Radiation Physics and Chemistry · doi:10.1016/1359-0197(86)90175-x
Amemiya, A. (1973) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.34.1347
Measurement of Weight Average Molecular Weight of Polymer
Saitô, O. (1966) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.21.204
Blachford, J., & Robertson, R. (1965) · Journal of Polymer Science Part A General Papers · doi:10.1002/pol.1965.100030406
Effect of gamma radiation on selected organic protective coatings
Johnson, J. W. (1958)
Kinetic modeling of the oxidative degradation of additive free PE in bleach disinfected water
Mikdam, A., Colin, X. A., Billon, N., & Minard, G. (2016) · AIP conference proceedings · doi:10.1063/1.4949614
9 Effect of Ionizing Radiation for Polymers
Saiki, S., & Seko, N. (2017) · RADIOISOTOPES · doi:10.3769/radioisotopes.66.469
Jacques Verdu, C. (2012) · doi:10.1002/9781118562598.biblio
Polymeric Nanogels and Nanoparticles in Medical Applications
Kadłubowski, S., de Lima, C. S. A., & Ferreira, A. H. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95486-0.00086-7
Bouffard, S. (2025) · doi:10.1002/9781394361861.ch9
Effect of Chemical Aging on Mechanical Properties
Richaud, E. (2025) · doi:10.1002/9781394417834.ch5
Osada, Y., & Dušek, K. (2026) · Springer eBooks · doi:10.1007/978-981-95-0301-8_3
Utilizing UV–Vis spectroscopy to detect and quantify ionizing radiation
Hack, B., Simmons, M., Kovacic, M., Krukowski, M., & Dan, D. (2026) · Journal of Hazardous Materials Advances · doi:10.1016/j.hazadv.2026.101027
Particle-volume distribution for coagulation and fragmentation phenomena
Alexandrov, D. V., & Makoveeva, E. V. (2026) · Applied Physics Letters · doi:10.1063/5.0347784
Kim, B., Woo, S. I., Chen, C., & Wee, J.-W. (2026) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2026.112539
Metadata
- Authors
- Saito, O.
- Affiliations
- Faculty of Engineering, Chuo University
- Venue
- Journal of the Physical Society of Japan
- Publisher
- Physical Society of Japan
- Published
- 1958-02
- Volume
- 13
- Issue
- 2
- Pages
- 198-206
- ISSN
- 0031-9015 (ISSN-L)
- 1347-4073
- OpenAlex
- W2012348634
- Cited by
- 235
- References
- 12
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 4 · 2023: 3 · 2022: 3 · 2021: 5 · 2020: 6 · 2019: 5 · 2018: 3 · 2017: 4 · 2016: 4 · 2015: 2 · 2014: 6 · 2013: 5 · 2012: 6
- FWCI
- 13.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the Physical Society of Japan (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer Nanocomposite Synthesis and Irradiation
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Advanced Physical and Chemical Molecular Interactions
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Theoretical and Computational Physics
- Keywords
- high-energy radiation, polymer irradiation, crosslinking, polymer degradation, gel point, molecular weight distribution, integro-differential equations, cyclization, branching, gelation, Poisson distribution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review