CoMon: a mostly-scalable monitoring system for PlanetLab
Abstract
CoMon is an evolving, mostly-scalable monitoring system for PlanetLab that has the goal of presenting environment-tailored information for both the administrators and users of the PlanetLab global testbed. In addition to passively reporting metrics provided by the operating system, CoMon also actively gathers a number of metrics useful for developers of networked systems. Using CoMon, PlanetLab administrators and users can easily spot problematic machines, where the problem may arise from the machine itself, local configuration/environment problems, or the workload running on the machine. Furthermore, users can easily observe many properties of all of the experiments running across multiple PlanetLab nodes, facilitating not only their own experiment monitoring and debugging, but also helping scale the task of finding PlanetLab problems.In this paper we describe CoMon's design and operation, including what kinds of data are gathered, the scale of the processing involved, and the approaches we have taken to keep CoMon running. Our goal is not only to illustrate the kinds of problems faced in this environment, but also to invite others to participate, either by experimenting with the data generated by CoMon, or by building on the CoMon system itself.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The ganglia distributed monitoring system: design, implementation, and experience
Massie, M. L., Chun, B. N., & Culler, D. (2004) · Parallel Computing · doi:10.1016/j.parco.2004.04.001 · Cited by 1,265
Simple Network Management Protocol-SNMP
(2003) · Network Tutorial · doi:10.1201/9781482280876-123 · Cited by 1,158
Simple Network Management Protocol (SNMP)
Case, J. D., Fedor, M., Schoffstall, M. L., & Davin, J. (1990) · doi:10.17487/rfc1157 · Cited by 912
Rhea, S. C., Godfrey, B., Karp, B. N., Kubiatowicz, J. D., Ratnasamy, S., Shenker, S. J., Stoica, I. G., & Yu, H. (2005) · ACM SIGCOMM Conference (SIGCOMM) · doi:10.1145/1080091.1080102 · Cited by 502
Reliability and security in the CoDeeN content distribution network
Wang, L., Park, K. S., Pang, R., Pai, V. S., & Peterson, L. (2004) · Cited by 201
Self-citation
Cited by
Beloglazov, A., & Buyya, R. (2012) · Concurrency and Computation: Practice and Experience · doi:10.1002/cpe.1867 · Cited by 1,864
A Framework and Algorithm for Energy Efficient Container Consolidation in Cloud Data Centers
Piraghaj, S. F., Dastjerdi, A. V., Calheiros, R. N., & Buyya, R. (2015) · 2015 IEEE International Conference on Data Science and Data Intensive Systems · doi:10.1109/dsdis.2015.67 · Cited by 118
A systematic review on effective energy utilization management strategies in cloud data centers
Panwar, S. S., Rauthan, M. M. S., & Barthwal, V. (2022) · Journal of Cloud Computing · doi:10.1186/s13677-022-00368-5 · Cited by 65
Xu, M., Zhou, Q., Wu, H., Lin, W., Ye, K., & Xu, C. (2022) · Software: Practice and Experience · doi:10.1002/spe.3014 · Cited by 35
An energy-efficient VM placement method for cloud data centers using a hybrid genetic algorithm
Kaaouache, M. A., & Bouamama, S. (2018) · Journal of Systems and Information Technology · doi:10.1108/jsit-10-2017-0089 · Cited by 18
Metadata
- Authors
- Park, K., & Pai, V. S.
- Venue
- ACM SIGOPS Operating Systems Review
- Published
- 2006-01
- Volume
- 40
- Issue
- 1
- Pages
- 65-74
- ISSN
- 0163-5980 (ISSN-L)
- OpenAlex
- W2034609836
- Cited by
- 585
- References
- 5
- FWCI
- 23.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CoMon: a mostly-scalable monitoring system for PlanetLab. https://app.cochat.ai/papers/10.1145/1113361.1113374
- The paper
- Park, K., & Pai, V. S. (2006). CoMon: a mostly-scalable monitoring system for PlanetLab. ACM SIGOPS Operating Systems Review. https://doi.org/10.1145/1113361.1113374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.