Light field microscopy
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
By inserting a microlens array into the optical train of a conventional microscope, one can capture light fields of biological specimens in a single photograph. Although diffraction places a limit on the product of spatial and angular resolution in these light fields, we can nevertheless produce useful perspective views and focal stacks from them. Since microscopes are inherently orthographic devices, perspective views represent a new way to look at microscopic specimens. The ability to create focal stacks from a single photograph allows moving or light-sensitive specimens to be recorded. Applying 3D deconvolution to these focal stacks, we can produce a set of cross sections, which can be visualized using volume rendering. In this paper, we demonstrate a prototype light field microscope (LFM), analyze its optical performance, and show perspective views, focal stacks, and reconstructed volumes for a variety of biological specimens. We also show that synthetic focusing followed by 3D deconvolution is equivalent to applying limited-angle tomography directly to the 4D light field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
GABOR, D. (1948) · Nature · doi:10.1038/161777a0 · Cited by 4,548
Levoy, M., & Hanrahan, P. (1996) · Proceedings of the 23rd annual conference on Computer graphics and interactive techniques · doi:10.1145/237170.237199 · Cited by 3,755
Self-citationHandbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Andersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
Light Field Photography with a Hand-held Plenoptic Camera
Ng, R., Levoy, M., Brédif, M., Duval, G., Horowitz, M., & Hanrahan, P. (2005) · HAL · Cited by 1,749
Self-citationSingle lens stereo with a plenoptic camera
Adelson, E. H., & Wang, J. Y. A. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121783 · Cited by 1,101
High performance imaging using large camera arrays
Wilburn, B., Joshi, N., Vaish, V., Talvala, E.-V., Antunez, E., Barth, A., Adams, A., Horowitz, M., & Levoy, M. (2005) · ACM Transactions on Graphics · doi:10.1145/1073204.1073259 · Cited by 1,042
Self-citationNg, R. (2005) · ACM Transactions on Graphics · doi:10.1145/1073204.1073256 · Cited by 574
Self-citationDigital light field photography
Hanrahan, P., & Ng, R. (2006) · Cited by 530
Self-citationDynamically reparameterized light fields
Isaksen, A., McMillan, L., & Gortler, S. J. (2000) · ACM SIGGRAPH Annual Conference on Computer Graphics and Interactive Techniques (SIGGRAPH) · doi:10.1145/344779.344929 · Cited by 507
Optical Sectioning Microscopy: Cellular Architecture in Three Dimensions
Agard, D. A. (1984) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.13.060184.001203 · Cited by 475
Deconvolution of images and spectra
Jansson, P. (1997) · Academic Press eBooks · Cited by 410
Three-dimensional imaging techniques
(1977) · Optics & Laser Technology · doi:10.1016/0030-3992(77)90118-9 · Cited by 385
Inoué, S., & Spring, K. R. (1997) · doi:10.1007/978-1-4615-5859-0 · Cited by 326
Synthetic aperture confocal imaging
Levoy, M., Chen, B., Vaish, V., Horowitz, M., McDowall, I., & Bolas, M. (2004) · ACM Transactions on Graphics · doi:10.1145/1015706.1015806 · Cited by 188
Self-citationWeinstein, R. S., Descour, M. R., Liang, C., Barker, G., Scott, K. M., Richter, L., Krupinski, E. A., Bhattacharyya, A. K., Davis, J. R., Graham, A. R., et al. (2004) · Human Pathology · doi:10.1016/j.humpath.2004.09.002 · Cited by 167
McVeigh, E. R. (2006) · Circulation Research · doi:10.1161/01.res.0000216870.73358.d9 · Cited by 159
Waves and Imaging through Complex Media
Sebbah, P. (2001) · Springer eBooks · doi:10.1007/978-94-010-0975-1 · Cited by 150
Light Microscopic Images Reconstructed by Maximum Likelihood Deconvolution
Holmes, T. J., Bhattacharyya, S., Cooper, J. A., Hanzel, D. K., Krishnamurthi, V., Lin, W., Roysam, B., Szarowski, D. H., & Turner, J. N. (1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6_24 · Cited by 133
Deconvolution in optical microscopy
Swedlow, J. R., Sedat, J. W., & Agard, D. A. (1996) · Academic Press, Inc. eBooks · Cited by 59
Artefacts in restored images due to intensity loss in three‐dimensional fluorescence microscopy
Markham, J., & Conchello, J. A. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00961.x · Cited by 31
Cited by
Wide-field, high-resolution Fourier ptychographic microscopy
Zheng, G., Horstmeyer, R., & Yang, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.187 · Cited by 1,829
Image and depth from a conventional camera with a coded aperture
Levin, A., Fergus, R., Durand, F., & Freeman, W. T. (2007) · ACM SIGGRAPH 2007 papers · doi:10.1145/1275808.1276464 · Cited by 1,023
Image and depth from a conventional camera with a coded aperture
Levin, A., Fergus, R., Durand, F., & Freeman, W. T. (2007) · ACM Transactions on Graphics · doi:10.1145/1276377.1276464 · Cited by 980
Simultaneous whole-animal 3D imaging of neuronal activity using light-field microscopy
Prevedel, R., Yoon, Y.-G., Hoffmann, M., Pak, N., Wetzstein, G., Kato, S., Schrödel, T., Raskar, R., Zimmer, M., Boyden, E. S., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2964 · Cited by 799
Light Field Image Processing: An Overview
Wu, G., Masia, B., Jarabo, A., Zhang, Y., Wang, L., Dai, Q., Chai, T., & Liu, Y. (2017) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2017.2747126 · Cited by 586
Metadata
- Authors
- Levoy, M., Ng, R., Adams, A., Footer, M., & Horowitz, M.
- Venue
- ACM Transactions on Graphics
- Published
- 2006-07
- Volume
- 25
- Issue
- 3
- Pages
- 924-934
- ISSN
- 0730-0301 (ISSN-L)
- 1557-7368
- OpenAlex
- W2060167709
- Cited by
- 730
- References
- 24
- FWCI
- 13.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.