The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
COMPASS: A probabilistic indoor positioning system based on 802.11 and digital compasses
Abstract
Positioning systems are one of the key elements required by location-based services. This paper presents the design, implementation and analysis of a positioning system called COMPASS which is based on 802.11-compliant network infrastructure and digital compasses. On the mobile device, COMPASS samples the signal strength values of different access points in its communication range and utilizes the orientation of the user to preselect a subset of the training data. The remaining training data is used by a probabilistic positioning algorithm to determine the position of the user. While prior systems show limited accuracy due to blocking effects caused by the human body, we apply digital compasses to detect the orientations of the users so that we can deal with these blocking effects. After a short period of training our COMPASS system achieves an average error distance of less than 1.65 meters in our experimental environment of 312 square meters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RADAR: an in-building RF-based user location and tracking system
Bahl, P., & Padmanabhan, V. N. (2002) · Proceedings IEEE INFOCOM 2000. Conference on Computer Communications. Nineteenth Annual Joint Conference of the IEEE Computer and Communications Societies (Cat. No.00CH37064) · doi:10.1109/infcom.2000.832252 · Cited by 8,380 · cited 6×
“Afterwards, we compare the performance of our system with the RADAR approach.”
BackgroundInfluentialThe Horus WLAN location determination system
Youssef, M., & Agrawala, A. (2005) · Proceedings of the 3rd international conference on Mobile systems, applications, and services · doi:10.1145/1067170.1067193 · Cited by 1,653
Cited by
A survey of indoor positioning systems for wireless personal networks
Gu, Y., Lo, A., & Niemegeers, I. (2009) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2009.090103 · Cited by 1,534
Recent Advances in Indoor Localization: A Survey on Theoretical Approaches and Applications
Yassin, A., Nasser, Y., Awad, M., Al-Dubai, A., Liu, R., Yuen, C., Raulefs, R., & Aboutanios, E. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2016.2632427 · Cited by 916
Location Fingerprinting with Bluetooth Low Energy Beacons
Faragher, R., & Harle, R. (2015) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2015.2430281 · Cited by 879
Localization Technologies for Indoor Human Tracking
Zhang, D., Xia, F., Yang, Z., Yao, L., & Zhao, W. (2010) · 2010 5th International Conference on Future Information Technology · doi:10.1109/futuretech.2010.5482731 · Cited by 267
Smart Pipe System for a Shipyard 4.0
Fraga-Lamas, P., Noceda-Davila, D., Fernández-Caramés, T., Díaz-Bouza, M., & Vilar-Montesinos, M. (2016) · Sensors · doi:10.3390/s16122186 · Cited by 73
“…[94] Different rooms RF + Ultrasound 10cm, orientation accuracy 3 ◦ Sonitor [95] Healthcare Ultrasound,Wi-Fi and LF Room level accuracy COMPASS [96] Office building (312m 2 ) Wi-Fi, no real-time tracking ∼ 1.65m OPT [97] Context aware app in personal network IEEE 802.15.4 1.5-3.8m Easy Living…”
BackgroundInfluential
Metadata
- Authors
- King, T., Kopf, S., Haenselmann, T., Lubberger, C., & Effelsberg, W.
- Venue
- Proceedings of the 1st international workshop on Wireless network testbeds, experimental evaluation & characterization
- Publisher
- ACM
- Published
- 2006-09-29
- Pages
- 34-40
- OpenAlex
- W2060141207
- Cited by
- 223
- References
- 2
- FWCI
- 18.04
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.