Practical motion capture in everyday surroundings
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Commercial motion-capture systems produce excellent in-studio reconstructions, but offer no comparable solution for acquisition in everyday environments. We present a system for acquiring motions almost anywhere. This wearable system gathers ultrasonic time-of-flight and inertial measurements with a set of inexpensive miniature sensors worn on the garment. After recording, the information is combined using an Extended Kalman Filter to reconstruct joint configurations of a body. Experimental results show that even motions that are traditionally difficult to acquire are recorded with ease within their natural settings. Although our prototype does not reliably recover the global transformation, we show that the resulting motions are visually similar to the original ones, and that the combined acoustic and inertial system reduces the drift commonly observed in purely inertial systems. Our final results suggest that this system could become a versatile input device for a variety of augmented-reality applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GELB, A. (1974) · CERN Document Server (European Organization for Nuclear Research) · Cited by 6,405
The Cricket location-support system
Priyantha, N. B., Chakraborty, A., & Balakrishnan, H. (2000) · Proceedings of the 6th annual international conference on Mobile computing and networking · doi:10.1145/345910.345917 · Cited by 3,716
Location systems for ubiquitous computing
Hightower, J., & Borriello, G. (2001) · Computer · doi:10.1109/2.940014 · Cited by 2,987
Pedestrian Tracking with Shoe-Mounted Inertial Sensors
Foxlin, E. (2005) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2005.140 · Cited by 1,399
A new location technique for the active office
Ward, A., Jones, A., & Hopper, A. (1997) · IEEE Personal Communications · doi:10.1109/98.626982 · Cited by 1,354
Haddad, A. H. (1976) · Proceedings of the IEEE · doi:10.1109/proc.1976.10175 · Cited by 802
Tracking people with twists and exponential maps
Bregler, C., & Malik, J. (2002) · Proceedings. 1998 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (Cat. No.98CB36231) · doi:10.1109/cvpr.1998.698581 · Cited by 719
Motion tracking: no silver bullet, but a respectable arsenal
Welch, G., & Foxlin, E. (2002) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2002.1046626 · Cited by 535
Automatic rigging and animation of 3D characters
Baran, I., & Popović, J. (2007) · ACM SIGGRAPH 2007 papers · doi:10.1145/1275808.1276467 · Cited by 495 · cited 1×
“The results are processed at a rate of 10 frames per second and visualized without any post-processing using an automatically skinned mesh [Baran and Popović 2007].”
MethodSelf-citationAutomatic rigging and animation of 3D characters
Baran, I., & Popović, J. (2007) · ACM Transactions on Graphics · doi:10.1145/1276377.1276467 · Cited by 455
Self-citation
Cited by
Human3.6M: Large Scale Datasets and Predictive Methods for 3D Human Sensing in Natural Environments
Ionescu, C., Papava, D., Olaru, V., & Sminchisescu, C. (2014) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2013.248 · Cited by 3,653
Sigal, L., Balan, A. O., & Black, M. J. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-009-0273-6 · Cited by 1,164
Recovering Accurate 3D Human Pose in the Wild Using IMUs and a Moving Camera
von Marcard, T., Henschel, R., Black, M. J., Rosenhahn, B., & Pons-Moll, G. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01249-6_37 · Cited by 1,058
(2009) · Cited by 701
Capturing the human figure through a wall
Adib, F., Hsu, C.-Y., Mao, H., Katabi, D., & Durand, F. (2015) · ACM Transactions on Graphics · doi:10.1145/2816795.2818072 · Cited by 443
“…methods place various types of sensors on the human body – including inertial, infrared, RF, acoustic, or ultrasonic sensors – and capture the human skeleton by tracking these various markers, e.g., [Roetenberg et al. 2009; Vlasic et al. 2007; Wang et al. 2014a; Raskar et al. 2007; VIC ; Zeb ].”
MethodHuang, Y., Kaufmann, M., Aksan, E., Black, M. J., Hilliges, O., & Pons-Moll, G. (2018) · ACM Transactions on Graphics · doi:10.1145/3272127.3275108 · Cited by 342
From wireless sensor networks towards cyber physical systems
Wu, F.-J., Kao, Y.-F., & Tseng, Y.-C. (2011) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2011.03.003 · Cited by 329
Sparse Inertial Poser: Automatic 3D Human Pose Estimation from Sparse IMUs
von Marcard, T., Rosenhahn, B., Black, M. J., & Pons-Moll, G. (2017) · Computer Graphics Forum · doi:10.1111/cgf.13131 · Cited by 304
RisQ: recognizing smoking gestures with inertial sensors on a wristband
Parate, A., Chiu, M.-C., Chadowitz, C., Ganesan, D., & Kalogerakis, E. (2014) · Proceedings of the 12th annual international conference on Mobile systems, applications, and services · doi:10.1145/2594368.2594379 · Cited by 282
Yi, X., Zhou, Y., Habermann, M., Shimada, S., Golyanik, V., Theobalt, C., & Xu, F. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.01282 · Cited by 223
“Some works [28,56,60] leverage ultrasonic sensors for additional position information to resolve some ambiguities, but the use of distance sensors limits the recording range.”
BackgroundTowards Miniaturization of a MEMS-Based Wearable Motion Capture System
Brigante, C. M. N., Abbate, N., Basile, A., Faulisi, A. C., & Sessa, S. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2148671 · Cited by 213
“The continuous-time nonlinear system equations are [13] ˙ x = f ( x, ω ) + w. (2.1) where x = [ q b ω ] T state of the system composed of the quaternion q = [ q 0 q 1 q 2 q 3 ] and the rate gyro bias and magnetic field [ m x m y m z ] .”
BackgroundInfluentialMotion reconstruction using sparse accelerometer data
Tautges, J., Zinke, A., Krüger, B., Baumann, J., Weber, A., Helten, T., Müller, M., Seidel, H.-P., & Eberhardt, B. (2011) · ACM Transactions on Graphics · doi:10.1145/1966394.1966397 · Cited by 197
Deep Neural Network-Based Cooperative Visual Tracking Through Multiple Micro Aerial Vehicles
Price, E., Lawless, G., Ludwig, R., Martinovic, I., Bulthoff, H. H., Black, M. J., & Ahmad, A. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2018.2850224 · Cited by 64
“arch in this field is focused on indoor scenarios, e.g., [13]. However, recent works have started to address the challenges of performing full body motion capture in unstructured everyday environments [14] and even in unknown outdoor scenarios [15]. Authors in [15] use body-fixed sensors (IMUs) to estimate the full body…”
BackgroundGeometrical kinematic modeling on human motion using method of multi-sensor fusion
Xu, C., He, J., Zhang, X., Yao, C., & Tseng, P.-H. (2018) · Information Fusion · doi:10.1016/j.inffus.2017.09.014 · Cited by 58
“Vlasic et al.[22] presented a system for acquiring motions with wearable sensors gathering ultrasonic time-of-flight and inertial measurements.”
BackgroundSun, Y., Greaves, D. A., Orgs, G., de C. Hamilton, A. F., Day, S., & Ward, J. A. (2023) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3580781 · Cited by 35
Metadata
- Authors
- Vlasic, D., Adelsberger, R., Vannucci, G., Barnwell, J., Gross, M., Matusik, W., & Popović, J.
- Venue
- ACM SIGGRAPH 2007 papers
- Publisher
- ACM
- Published
- 2007-07-29
- Pages
- 35
- OpenAlex
- W2110331760
- Cited by
- 269
- References
- 24
- FWCI
- 31.52
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.