The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Specifying gestures by example
Abstract
Gesture-Based interfaces offer an alternative to traditional keyboard, menu, and direct manipulation interfaces. The ability to specify objects, an operation, and additional parameters with a single intuitive gesture appeals to both novice and experienced users. Unfortunately, gesture-based interfaces have not been extensively researched, partly because they are difficult to create. This paper describes GRANDMA, a toolkit for rapidly adding gestures to direct manipulation interfaces. The trainable single-stroke gesture recognizer used by GRANDMA is also described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A hand gesture interface device
Zimmerman, T. G., Lanier, J., Blanchard, C., Bryson, S., & Harvill, Y. (1987) · ACM SIGCHI Bulletin · doi:10.1145/1165387.275628 · Cited by 396
Automatic recognition of handprinted characters—The state of the art
Suen, C. Y., Berthod, M., & Mori, S. (1980) · Proceedings of the IEEE · doi:10.1109/proc.1980.11675 · Cited by 286
A hand gesture interface device
Zimmerman, T. G., Lanier, J., Blanchard, C., Bryson, S., & Harvill, Y. (1986) · Proceedings of the SIGCHI/GI Conference on Human Factors in Computing Systems and Graphics Interface · doi:10.1145/29933.275628 · Cited by 224
A multi-touch three dimensional touch-sensitive tablet
Lee, S., Buxton, W. A. S., & Smith, K. C. (1985) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/317456.317461 · Cited by 91
Integrating gesture and snapping into a user interface toolkit
Henry, T. R., Hudson, S. E., & Newell, G. L. (1990) · doi:10.1145/97924.97938 · Cited by 84
Cited by
Online and off-line handwriting recognition: a comprehensive survey
Plamondon, R., & Srihari, S. N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824821 · Cited by 2,498
Past, present, and future of user interface software tools
Myers, B., Hudson, S. E., & Pausch, R. (2000) · ACM Transactions on Computer-Human Interaction · doi:10.1145/344949.344959 · Cited by 808
SKETCH: an interface for sketching 3D scenes
Zeleznik, R. C., Herndon, K. P., & Hughes, J. F. (2006) · ACM SIGGRAPH 2006 Courses on - SIGGRAPH '06 · doi:10.1145/1185657.1185770 · Cited by 650
Interactive sketching for the early stages of user interface design
Landay, J. A., & Myers, B. A. (1995) · Proceedings of the SIGCHI conference on Human factors in computing systems - CHI '95 · doi:10.1145/223904.223910 · Cited by 543
Sketching interfaces: toward more human interface design
Landay, J. A., & Myers, B. A. (2001) · Computer · doi:10.1109/2.910894 · Cited by 482
Metadata
- Authors
- Rubine, D.
- Venue
- ACM SIGGRAPH Computer Graphics
- Published
- 1991-07
- Volume
- 25
- Issue
- 4
- Pages
- 329-337
- ISSN
- 0097-8930 (ISSN-L)
- OpenAlex
- W3000063644
- Cited by
- 407
- References
- 5
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Specifying gestures by example. https://app.cochat.ai/papers/10.1145/127719.122753
- The paper
- Rubine, D. (1991). Specifying gestures by example. ACM SIGGRAPH Computer Graphics. https://doi.org/10.1145/127719.122753
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.