The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Number of people required for usability evaluation: the 10±2 rule
Abstract
Introduction Usability evaluation is essential to make sure that software products newly released are easy to use, efficient, and effective to reach goals, and satisfactory to users. For example, when a software company wants to develop and sell a new product, the company needs to evaluate usability of the new product before launching it at a market to avoid the possibility that the new product may contain usability problems, which span from cosmetic problems to severe functional problems. Three widely used methods for usability evaluation are Think Aloud (TA), Heuristic Evaluation (HE) and Cognitive Walkthrough (CW). TA method is commonly employed with a lab-based user testing, while there are variants of TA methods, including thinking out aloud at user's workplace instead of at labs. What we discuss here is the TA method that is combined with a lab-based user testing, in which test users use products while simultaneously and continuously thinking out aloud, and experimenters record users' behaviors and verbal protocols in the laboratory. HE is a usability inspection method, in which a small number of evaluators find usability problems in a user interface design by examining an interface and judging its compliance with well-known usability principles, called heuristics. CW is a theory-based method, in which evaluators evaluate every step necessary to perform a scenario-based task, and look for usability problems that would interfere with learning by exploration. These three methods have their own advantages and disadvantages. For instance, TA method provides good qualitative data from a small number of test users, but laboratory environment may influence test user's behaviors. HE is a cheap, fast and easy-to-use method, while it often finds too specific and low-priority usability problems, including even not real problems. CW helps find mismatches between users' and designers' conceptualization of a task, but it needs extensive knowledge of cognitive psychology and technical details to apply. However, even though these advantages and disadvantages show overall characteristics of three major usability evaluation methods, we cannot compare them quantitatively and see their efficiency clearly. Because one of reasons why so-called discounted methods, such as HE and CW, were developed is to save costs of usability evaluation, cost-related criteria for comparing usability evaluation are meaningful to usability practitioners as well as usability researchers. One of the most disputable issues related to cost of usability evaluation is sample size. That is, how many users or evaluators are needed to achieve a targeted usability evaluation performance, for example, 80% of overall discovery rate? The sample size of usability evaluation is known to depend on an estimate of problem discovery rate across participants. The overall discovery rate is a common quantitative measure that is used to show the effectiveness of a specific usability evaluation method in most of usability evaluation studies. It is also called overall detection rate or thoroughness measure, which is the ratio of 'the sum of unique usability problems detected by all experiment participants' against 'the number of usability problems that exist in the evaluated systems', ranging between 0 and 1. The overall discovery rates were reported more than any other criterion measure in the usability evaluation experiments and also a key component for projecting required sample size for usability evaluation study. Thus, how many test users or evaluators participate in the usability evaluation is a critical issue, considering its cost-effectiveness.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, a sample size of 10±2 is sufficient for discovering 80 per cent of usability issues [55].”
From A user-centred design framework for mHealth (2020) · cites this paper as [55]
Citations
Cites
Heuristic evaluation of user interfaces
Nielsen, J., & Molich, R. (1990) · Proceedings of the SIGCHI conference on Human factors in computing systems Empowering people - CHI '90 · doi:10.1145/97243.97281 · Cited by 3,533
Refining the Test Phase of Usability Evaluation: How Many Subjects Is Enough?
Virzi, R. A. (1992) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872089203400407 · Cited by 1,190
Estimating the number of subjects needed for a thinking aloud test
Nielsen, J. (1994) · International Journal of Human-Computer Studies · doi:10.1006/ijhc.1994.1065 · Cited by 476
Sample sizes for usability studies: Additional considerations
Lewis, J. R. (1994) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872089403600215 · Cited by 341
What is gained and lost when using evaluation methods other than empirical testing
Desurvire, H., Kondziela, J. M., & Atwood, M. E. (1993) · Cited by 107
Relaxing the homogeneity assumption in usability testing
Caulton, D. A. (2001) · Behaviour and Information Technology · doi:10.1080/01449290010020648 · Cited by 101
Evaluation of Procedures for Adjusting Problem-Discovery Rates Estimated From Small Samples
Lewis, J. R. (2001) · International Journal of Human-Computer Interaction · doi:10.1207/s15327590ijhc1304_06 · Cited by 76
Law, L.-C., & Hvannberg, E. Þ. (2002) · Nordic Conference on Human-Computer Interaction · doi:10.1145/572020.572030 · Cited by 69
Analysis of combinatorial user effect in international usability tests
Law, E. L., & Hvannberg, E. Þ. (2004) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/985692.985694 · Cited by 63
Novice heuristic evaluations of a complex interface
Slavković, A., & Cross, K. (1999) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/632716.632902 · Cited by 28
Cited by
Local Standards for Sample Size at CHI
Caine, K. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858498 · Cited by 657
Usability: Lessons Learned … and Yet to Be Learned
Lewis, J. R. (2014) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2014.930311 · Cited by 311
Improving service quality through customer journey analysis
Halvorsrud, R., Kvale, K., & Følstad, A. (2016) · Journal of Service Theory and Practice · doi:10.1108/jstp-05-2015-0111 · Cited by 267
A user-centred design framework for mHealth
Farao, J., Malila, B., Conrad, N., Mutsvangwa, T., Rangaka, M. X., & Douglas, T. S. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237910 · Cited by 203
“However, a sample size of 10±2 is sufficient for discovering 80 per cent of usability issues [55].”
BackgroundSample size in usability studies
Schmettow, M. (2012) · Communications of the ACM · doi:10.1145/2133806.2133824 · Cited by 123
Metadata
- Authors
- Hwang, W., & Salvendy, G.
- Affiliations
- Soongsil University (KR)
- Purdue University West Lafayette (US)
- ORCID
- Hwang, Wonil
- Venue
- Communications of the ACM
- Published
- 2010-05
- Volume
- 53
- Issue
- 5
- Pages
- 130-133
- ISSN
- 0001-0782 (ISSN-L)
- 1557-7317
- OpenAlex
- W2016022053
- Cited by
- 410
- References
- 11
- Citations by year
- 2026: 40 · 2025: 36 · 2024: 26 · 2023: 43 · 2022: 27 · 2021: 21 · 2020: 29 · 2019: 30 · 2018: 22 · 2017: 24 · 2016: 23 · 2015: 15 · 2014: 24 · 2013: 17 · 2012: 17
- FWCI
- 31.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Communications of the ACM (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
- Physical Sciences › Computer Science › Information Systems › Software Engineering Techniques and Practices
- Social Sciences › Human Factors and Ergonomics › Human-Automation Interaction and Safety
- Keywords
- usability evaluation, sample size, think-aloud, heuristic evaluation, cognitive walkthrough, detection rate, evaluation costs, user interface design, verbal protocols, user testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Number of people required for usability evaluation: the 10±2 rule. https://app.cochat.ai/papers/10.1145/1735223.1735255
- The paper
- Hwang, W., & Salvendy, G. (2010). Number of people required for usability evaluation: the 10±2 rule. Communications of the ACM. https://doi.org/10.1145/1735223.1735255
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.