Steadied-bubbles: combining techniques to address pen-based pointing errors for younger and older adults
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Tablet PCs are gaining popularity but many older adults still struggle with pointing, particularly with two error types: missing, landing and lifting outside the target bounds; and slipping, landing on the target, but slipping off before lifting. To solve these problems, we examined the feasibility of extending and combining existing techniques designed for younger users and the mouse, focusing our investigation on the Bubble cursor and Steady Clicks techniques. Through a laboratory experiment with younger and older adults, we showed that both techniques can be adapted for use in a pen interface, and that combining the two techniques provides greater support than either technique on its own. Though our results were especially pertinent to the older group, both ages benefited from the designs. We also found that technique performance depended on task context. From these findings we established guidelines for technique selection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of age and Parkinson's disease on cursor positioning using a mouse
Keates, S., & Trewin, S. (2005) · Proceedings of the 7th international ACM SIGACCESS conference on Computers and accessibility · doi:10.1145/1090785.1090800 · Cited by 100 · cited 2×
“They have also been found to cover less distance with their primary movement [13], to make more submovements en route [12], to make less smooth movements [27], and to have difficulty staying on the target while clicking [22].”
BackgroundLight Pen Use and Practice Minimize Age and Hand Performance Differences in Pointing Tasks
Charness, N., Holley, P., Feddon, J., & Jastrzembski, T. (2004) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/hfes.46.3.373.50396 · Cited by 90
Trewin, S., Keates, S., & Moffatt, K. (2006) · Proceedings of the 8th international ACM SIGACCESS conference on Computers and accessibility · doi:10.1145/1168987.1168993 · Cited by 87 · cited 17×
“Steady Clicks is a mouse-based technique designed to help in situations where the user successfully clicks down on a target but slips off before releasing [23].”
BackgroundMethodInfluentialSelf-citationGoal Crossing with Mice and Trackballs for People with Motor Impairments
Wobbrock, J. O., & Gajos, K. Z. (2008) · ACM Transactions on Accessible Computing · doi:10.1145/1361203.1361207 · Cited by 68 · cited 1×
“Others have expanded on their ideas; for example, by investigating fluid multi-action sequences [2], and their use for supporting motor-impaired users [25].”
Background
Cited by
Ability-Based Design: Concept, Principles and Examples
Wobbrock, J. O., Kane, S. K., Gajos, K. Z., Harada, S., & Froehlich, J. (2011) · ACM Transactions on Accessible Computing · doi:10.1145/1952383.1952384 · Cited by 567
Enhanced area cursors: reducing fine pointing demands for people with motor impairments
Findlater, L., Jansen, A., Shinohara, K., Dixon, M., Kamb, P., Rakita, J., & Wobbrock, J. O. (2010) · Proceedings of the 23nd annual ACM symposium on User interface software and technology · doi:10.1145/1866029.1866055 · Cited by 98
Effects of Aging on Small Target Selection with Touch Input
Sultana, A., & Moffatt, K. (2019) · ACM Transactions on Accessible Computing · doi:10.1145/3300178 · Cited by 14
Self-citationWobbrock, J. O. (2014) · Advances in Medical Technologies and Clinical Practice · doi:10.4018/978-1-4666-4438-0.ch008 · Cited by 12
Martin-Hammond, A., Patil, U., & Tandukar, B. (2021) · Proceedings of the 23rd International ACM SIGACCESS Conference on Computers and Accessibility · doi:10.1145/3441852.3476472 · Cited by 7
Metadata
- Authors
- Moffatt, K., & McGrenere, J.
- Venue
- Proceedings of the SIGCHI Conference on Human Factors in Computing Systems
- Publisher
- ACM
- Published
- 2010-04-10
- Pages
- 1125-1134
- OpenAlex
- W2157066061
- Cited by
- 23
- References
- 4
- FWCI
- 1.47
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.