Development of the PowerCyber SCADA security testbed
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Meeting current demands for critical infrastructure cyber security education and research will require accurate testbed development. The PowerCyber was designed to closely resemble power grid communication utilizing actual field devices and SCADA software. The testbed provides a novel environment where students can explore cyber attacks and defenses while evaluating their impact on power flow. This paper documents the design and implementation of the testbed while proposing cyber attack scenarios which will negatively affect grid operations. In addition, it documents the results of an initial cyber vulnerability assessment to evaluate the security posture of the current design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guide to Industrial Control Systems (ICS) Security
Stouffer, K., Pillitteri, V., Lightman, S., Abrams, M., & Hahn, A. (2015) · doi:10.6028/nist.sp.800-82r2 · Cited by 1,377
Self-citationA testbed for secure and robust SCADA systems
Giani, A., Karsai, G., Roosta, T., Shah, A., Sinopoli, B., & Wiley, J. (2008) · ACM SIGBED Review · doi:10.1145/1399583.1399587 · Cited by 94
Cited by
Cyber–Physical System Security for the Electric Power Grid
Sridhar, S., Hahn, A., & Govindarasu, M. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165269 · Cited by 1,208
Self-citationCybersecurity for industrial control systems: A survey
Bhamare, D., Zolanvari, M., Erbad, A., Jain, R., Khan, K., & Meskin, N. (2020) · Computers & Security · doi:10.1016/j.cose.2019.101677 · Cited by 394
“[13] The PowerCyber testbed has been designed to resemble power grid communication utilizing actual field devices and SCADA software”
MethodA survey of cyber security management in industrial control systems
Knowles, W., Prince, D., Hutchison, D., Disso, J. F. P., & Jones, K. (2015) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2015.02.002 · Cited by 344
“[88] who use industrial control system testbeds with real devices, instrumentation and communications protocols.”
BackgroundAccurate modeling of modbus/TCP for intrusion detection in SCADA systems
Goldenberg, N., & Wool, A. (2013) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2013.05.001 · Cited by 323
Lin, H., Veda, S. S., Shukla, S. S., Mili, L., & Thorp, J. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2191805 · Cited by 259
Metadata
- Authors
- Hahn, A., Kregel, B., Govindarasu, M., Fitzpatrick, J., Adnan, R., Sridhar, S., & Higdon, M.
- Venue
- Proceedings of the Sixth Annual Workshop on Cyber Security and Information Intelligence Research
- Publisher
- ACM
- Published
- 2010-04-21
- Pages
- 1-4
- OpenAlex
- W2028727038
- Cited by
- 64
- References
- 2
- FWCI
- 10.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.