Benefits and limitations of tapping into stored energy for datacenters

Govindan, Sriram, Sivasubramaniam, Anand, Urgaonkar, Bhuvan·2011·Proceedings of the 38th annual international symposium on Computer architecture

Abstract

Datacenter power consumption has a significant impact on both its recurring electricity bill (Op-ex) and one-time construction costs (Cap-ex). Existing work optimizing these costs has relied primarily on throttling devices or workload shaping, both with performance degrading implications. In this paper, we present a novel knob of energy buffer (eBuff) available in the form of UPS batteries in datacenters for this cost optimization. Intuitively, eBuff stores energy in UPS batteries during "valleys" - periods of lower demand, which can be drained during "peaks" - periods of higher demand. UPS batteries are normally used as a fail-over mechanism to transition to captive power sources upon utility failure. Furthermore, frequent discharges can cause UPS batteries to fail prematurely. We conduct detailed analysis of battery operation to figure out feasible operating regions given such battery lifetime and datacenter availability concerns. Using insights learned from this analysis, we develop peak reduction algorithms that combine the UPS battery knob with existing throttling based techniques for minimizing datacenter power costs. Using an experimental platform, we offer insights about Op-ex savings offered by eBuff for a wide range of workload peaks/valleys, UPS provisioning, and application SLA constraints. We find that eBuff can be used to realize 15-45% peak power reduction, corresponding to 6-18% savings in Op-ex across this spectrum. eBuff can also play a role in reducing Cap-ex costs by allowing tighter overbooking of power infrastructure components and we quantify the extent of such Cap-ex savings. To our knowledge, this is the first paper to exploit stored energy - typically lying untapped in the datacenter - to address the peak power draw problem.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/2000064.2000105

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 223

Metadata

Authors
Govindan, S., Sivasubramaniam, A., & Urgaonkar, B.
Venue
Proceedings of the 38th annual international symposium on Computer architecture
Publisher
ACM
Published
2011-06-04
Pages
341-352
ISSN
1063-6897 (ISSN-L)
OpenAlex
W2164466478
Cited by
223
References
0
FWCI
21.15
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Benefits and limitations of tapping into stored energy for datacenters. https://app.cochat.ai/papers/10.1145/2000064.2000105
The paper
Govindan, S., Sivasubramaniam, A., & Urgaonkar, B. (2011). Benefits and limitations of tapping into stored energy for datacenters. Proceedings of the 38th annual international symposium on Computer architecture. https://doi.org/10.1145/2000064.2000105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.