The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
PreHeat: controlling home heating using occupancy prediction
Abstract
Home heating is a major factor in worldwide energy use. Our system, PreHeat, aims to more efficiently heat homes by using occupancy sensing and occupancy prediction to automatically control home heating. We deployed PreHeat in five homes, three in the US and two in the UK. In UK homes, we controlled heating on a per-room basis to enable further energy savings. We compared PreHeat's prediction algorithm with a static program over an average 61 days per house, alternating days between these conditions, and measuring actual gas consumption and occupancy. In UK homes PreHeat both saved gas and reduced MissTime (the time that the house was occupied but not warm). In US homes, PreHeat decreased MissTime by a factor of 6-12, while consuming a similar amount of gas. In summary, PreHeat enables more efficient heating while removing the need for users to program thermostat schedules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hargreaves, T., Nye, M., & Burgess, J. (2010) · Energy Policy · doi:10.1016/j.enpol.2010.05.068 · Cited by 801
The smart thermostat: using occupancy sensors to save energy in homes
Lu, J., Sookoor, T., Srinivasan, V., Gao, G., Holben, B., Stankovic, J., Field, E., & Whitehouse, K. (2010) · Proceedings of the 8th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/1869983.1870005 · Cited by 502
Measured energy savings from a more informative energy bill
Wilhite, H., & Ling, R. (1995) · Energy and Buildings · doi:10.1016/0378-7788(94)00912-4 · Cited by 282
Gupta, M., INTILLE, S. S., & Larson, K. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-01516-8_8 · Cited by 112
The Neurothermostat: Predictive Optimal Control of Residential Heating Systems
Mozer, M. C., Vidmar, L., & Dodier, R. H. (1996) · Cited by 73
Cited by
Candanedo, L. M., & Feldheim, V. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.071 · Cited by 586
A Survey on Concepts, Applications, and Challenges in Cyber-Physical Systems
(2014) · KSII Transactions on Internet and Information Systems · doi:10.3837/tiis.2014.12.001 · Cited by 392
Using machine learning techniques for occupancy-prediction-based cooling control in office buildings
Peng, Y., Rysanek, A., Nagy, Z., & Schlüter, A. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.002 · Cited by 332
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
A critical review of field implementations of occupant-centric building controls
Park, J. Y., Ouf, M. M., Gunay, B., Peng, Y., O'Brien, W., Kjærgaard, M. B., & Nagy, Z. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106351 · Cited by 274
Metadata
- Authors
- Scott, J., Bernheim Brush, A. J., Krumm, J., Meyers, B., Hazas, M., Hodges, S., & Villar, N.
- Venue
- Proceedings of the 13th international conference on Ubiquitous computing
- Publisher
- ACM
- Published
- 2011-09-17
- Pages
- 281-290
- OpenAlex
- W2096667387
- Cited by
- 379
- References
- 5
- FWCI
- 93.95
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PreHeat: controlling home heating using occupancy prediction. https://app.cochat.ai/papers/10.1145/2030112.2030151
- The paper
- Scott, J., Bernheim Brush, A. J., Krumm, J., Meyers, B., Hazas, M., Hodges, S., & Villar, N. (2011). PreHeat: controlling home heating using occupancy prediction. Proceedings of the 13th international conference on Ubiquitous computing. https://doi.org/10.1145/2030112.2030151
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.