Temperature management in data centers: why some (might) like it hot
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The energy consumed by data centers is starting to make up a significant fraction of the world's energy consumption and carbon emissions. A large fraction of the consumed energy is spent on data center cooling, which has motivated a large body of work on temperature management in data centers. Interestingly, a key aspect of temperature management has not been well understood: controlling the setpoint temperature at which to run a data center's cooling system. Most data centers set their thermostat based on (conservative) suggestions by manufacturers, as there is limited understanding of how higher temperatures will affect the system. At the same time, studies suggest that increasing the temperature setpoint by just one degree could save 2-5% of the energy consumption. This paper provides a multi-faceted study of temperature management in data centers. We use a large collection of field data from different production environments to study the impact of temperature on hardware reliability, including the reliability of the storage subsystem, the memory subsystem and server reliability as a whole. We also use an experimental testbed based on a thermal chamber and a large array of benchmarks to study two other potential issues with higher data center temperatures: the effect on server performance and power. Based on our findings, we make recommendations for temperature management in data centers, that create the potential for saving energy, while limiting negative effects on system reliability and performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic local alignment search tool
Altschul, S. F., Gish, W., Miller, W., Myers, E. W., & Lipman, D. J. (1990) · Journal of Molecular Biology · doi:10.1006/jmbi.1990.9999 · Cited by 98,669
lmbench: Portable Tools for Performance Analysis
McVoy, L., Staelin, C., & Laboratories, H.-P. (1996) · Cited by 916
Failure trends in a large disk drive population
Pinheiro, E., Weber, W.-D., & Barroso, L. A. (2007) · File and Storage Technologies · Cited by 814
Disk failures in the real world: what does an MTTF of 1,000,000 hours mean to you?
Schroeder, B., & Gibson, G. A. (2007) · Cited by 762
Self-citationA large-scale study of failures in high-performance computing systems
Schroeder, B., & Gibson, G. A. (2006) · International Conference on Dependable Systems and Networks (DSN'06) · doi:10.1109/dsn.2006.5 · Cited by 584
Self-citationDRAM errors in the wild: a large-scale field study
Schroeder, B., Pinheiro, E., & Weber, W.-D. (2009) · Proceedings of the eleventh international joint conference on Measurement and modeling of computer systems · doi:10.1145/1555349.1555372 · Cited by 557 · cited 2×
“An overview of Google’s measurement infrastructure is provided in [32].”
BackgroundSelf-citationTransaction Processing Performance Council
(2019) · Encyclopedia of Big Data Technologies · doi:10.1007/978-3-319-77525-8_100350 · Cited by 529
Load balancing and unbalancing for power and performance in cluster-based systems
Bianchini, R., Carrera, E. V., Heath, T., & Pinheiro, E. (2001) · doi:10.7282/t3-agfw-yt73 · Cited by 479 · cited 1×
“Approaches that have been investigated include, for example, methods to minimize air flow inefficiencies [23, 35], load balancing and the incorporation of temperature awareness into workload placement in data centers [7, 25, 28, 33], and power reduction features in individual servers [14, 15].”
MethodOptimal power allocation in server farms
Gandhi, A., Harchol-Balter, M., Das, R., & Lefurgy, C. (2009) · Proceedings of the eleventh international joint conference on Measurement and modeling of computer systems · doi:10.1145/1555349.1555368 · Cited by 457 · cited 1×
“Approaches that have been investigated include, for example, methods to minimize air flow inefficiencies [23, 35], load balancing and the incorporation of temperature awareness into workload placement in data centers [7, 25, 28, 33], and power reduction features in individual servers [14, 15].”
MethodBalance of Power: Dynamic Thermal Management for Internet Data Centers
Sharma, R. K., Bash, C. E., Patel, C. D., Friedrich, R. J., & Chase, J. S. (2005) · IEEE Internet Computing · doi:10.1109/mic.2005.10 · Cited by 443 · cited 1×
“Approaches that have been investigated include, for example, methods to minimize air flow inefficiencies [23, 35], load balancing and the incorporation of temperature awareness into workload placement in data centers [7, 25, 28, 33], and power reduction features in individual servers [14, 15].”
Method
Research works printed but not linked: 14
- 10.1016/S0022-2836(05)80360-2 · doi:10.1016/s0022-2836(05)80360-2 · Paper page
- C. Belady , A. Rawson , J. Pfleuger , and T. Cader . The Green Grid Data Center Power Efficiency Metrics: PUE & DCiE. Technical report , Green Grid , 2008 . C. Belady, A. Rawson, J. Pfleuger, and T. Cader. The Green Grid Data Center Power Efficiency Metrics: PUE & DCiE. Technical report, Green Grid, 2008.
- 10.1147/rd.475.0703 · doi:10.1147/rd.475.0703
- J. Brandon . Going Green In The Data Center: Practical Steps For Your SME To Become More Environmentally Friendly . Processor , 29, Sept. 2007 . J. Brandon. Going Green In The Data Center: Practical Steps For Your SME To Become More Environmentally Friendly. Processor, 29, Sept. 2007.
- G. Cole . Estimating drive reliability in desktop computers and consumer electronics systems. TP-338.1. Seagate . 2000 . G. Cole. Estimating drive reliability in desktop computers and consumer electronics systems. TP-338.1. Seagate. 2000.
- 10.5555/1060289.1060300 · doi:10.5555/1060289.1060300
- J. M. Kaplan , W. Forrest , and N. Kindler . Revolutionizing data center energy efficiency. Technical report , McKinsey & Company , July 2008 . J. M. Kaplan, W. Forrest, and N. Kindler. Revolutionizing data center energy efficiency. Technical report, McKinsey & Company, July 2008.
- J. D. McCalpin . Memory bandwidth and machine balance in current high performance computers . IEEE Comp. Soc. TCCA Newsletter , pages 19 -- 25 , Dec. 1995 . J. D. McCalpin. Memory bandwidth and machine balance in current high performance computers. IEEE Comp. Soc. TCCA Newsletter, pages 19--25, Dec. 1995.
- 10.1109/CLUSTR.2006.311859 · doi:10.1109/clustr.2006.311859
- 10.5555/1153924.1154555 · doi:10.5555/1153924.1154555
- C. Staelin . Lmbench3 : Measuring scalability. Technical report , HP Laboratories Israel , 2002 . C. Staelin. Lmbench3: Measuring scalability. Technical report, HP Laboratories Israel, 2002.
- R. F. Sullivan . Alternating Cold and Hot Aisles Provides More Reliable Cooling for Server Farms . In Uptime Institute , 2000 . R. F. Sullivan. Alternating Cold and Hot Aisles Provides More Reliable Cooling for Server Farms. In Uptime Institute, 2000.
- Transaction Processing Performance Council . TPC Benchmark C - Rev. 5.11. Standard , Feb. 2010 . Transaction Processing Performance Council. TPC Benchmark C - Rev. 5.11. Standard, Feb. 2010.
- 10.1145/358274.358283 · doi:10.1145/358274.358283
Cited by
Barroso, L. A., Clidaras, J., & Hölzle, U. (2013) · Synthesis lectures on computer architecture · doi:10.2200/s00516ed2v01y201306cac024 · Cited by 489
Adaptive-latency DRAM: Optimizing DRAM timing for the common-case
Lee, D., Kim, Y., Pekhimenko, G., Khan, S., Seshadri, V., Chang, K., & Mutlu, O. (2015) · 2015 IEEE 21st International Symposium on High Performance Computer Architecture (HPCA) · doi:10.1109/hpca.2015.7056057 · Cited by 241
“Other works [11, 12, 43] report similar results, as explained in detail in Footnote 2.”
BackgroundResultInfluentialMemory Errors in Modern Systems: The Good, The Bad, and The Ugly
Sridharan, V., DeBardeleben, N., Blanchard, S., Ferreira, K. B., Stearley, J., Shalf, J., & Gurumurthi, S. (2015) · Proceedings of the Twentieth International Conference on Architectural Support for Programming Languages and Operating Systems · doi:10.1145/2694344.2694348 · Cited by 237
“published a study on temperature effects of DRAM in data center environments [14].”
BackgroundAVATAR: A Variable-Retention-Time (VRT) Aware Refresh for DRAM Systems
Qureshi, M. K., Kim, D.-H., Khan, S., Nair, P. J., & Mutlu, O. (2015) · 2015 45th Annual IEEE/IFIP International Conference on Dependable Systems and Networks · doi:10.1109/dsn.2015.58 · Cited by 218
“Our experimental temperature closely matches to typical operating temperature as prior works show that even with 100% utilization, temperature in server and desktop systems remain in the range of 40−60 ◦C [9,25].”
ResultChang, K. K., Kashyap, A., Hassan, H., Ghose, S., Hsieh, K., Lee, D., Li, T., Pekhimenko, G., Khan, S., & Mutlu, O. (2016) · Proceedings of the 2016 ACM SIGMETRICS International Conference on Measurement and Modeling of Computer Science · doi:10.1145/2896377.2901453 · Cited by 158
“Temperature is an important external factor that may affect the reliability of DIMMs [12, 29, 43, 63].”
BackgroundApplication of virtual machine consolidation in cloud computing systems
Zolfaghari, R., Sahafi, A., Rahmani, A. M., & Rezaei, R. (2021) · Sustainable Computing: Informatics and Systems · doi:10.1016/j.suscom.2021.100524 · Cited by 33
Polverini, D., Ardente, F., Sanchez, I., Mathieux, F., Tecchio, P., & Beslay, L. (2018) · Computers & Security · doi:10.1016/j.cose.2017.12.001 · Cited by 28
“Furthermore, these products are typically operated at temperature in the range of 20–22 °C (El-Sayed et al., 2012), as discussed more in detail in the next sections.”
BackgroundInfluentialReliability of SSDs in Enterprise Storage Systems: A Large-Scale Field Study
Maneas, S., Mahdaviani, K., Emami, T., & Schroeder, B. (2021) · ACM Transactions on Storage · doi:10.1145/3423088 · Cited by 13
Self-citation
Metadata
- Authors
- El-Sayed, N., Stefanovici, I. A., Amvrosiadis, G., Hwang, A. A., & Schroeder, B.
- Venue
- Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems
- Publisher
- ACM
- Published
- 2012-06-11
- Pages
- 163-174
- OpenAlex
- W2101221989
- Cited by
- 196
- References
- 16
- FWCI
- 14.24
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.