Renewable and cooling aware workload management for sustainable data centers
Abstract
Recently, the demand for data center computing has surged, increasing the total energy footprint of data centers worldwide. Data centers typically comprise three subsystems: IT equipment provides services to customers; power infrastructure supports the IT and cooling equipment; and the cooling infrastructure removes heat generated by these subsystems. This work presents a novel approach to model the energy flows in a data center and optimize its operation. Traditionally, supply-side constraints such as energy or cooling availability were treated independently from IT workload management. This work reduces electricity cost and environmental impact using a holistic approach that integrates renewable supply, dynamic pricing, and cooling supply including chiller and outside air cooling, with IT workload planning to improve the overall sustainability of data center operations. Specifically, we first predict renewable energy as well as IT demand. Then we use these predictions to generate an IT workload management plan that schedules IT workload and allocates IT resources within a data center according to time varying power supply and cooling efficiency. We have implemented and evaluated our approach using traces from real data centers and production systems. The results demonstrate that our approach can reduce both the recurring power costs and the use of non-renewable energy by as much as 60% compared to existing techniques, while still meeting the Service Level Agreements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Habibi Khalaj, A., & Halgamuge, S. K. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.08.037 · Cited by 707
Joint Service Caching and Task Offloading for Mobile Edge Computing in Dense Networks
Xu, J., Chen, L., & Zhou, P. (2018) · IEEE INFOCOM 2018 - IEEE Conference on Computer Communications · doi:10.1109/infocom.2018.8485977 · Cited by 585
Carbon-aware computing for datacenters
Radovanović, A., Koningstein, R., Schneider, I., Chen, B., Duarte, A., Roy, B., Xiao, D., Haridasan, M., Hung, P., Care, N., et al. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3173250 · Cited by 353
Kwon, S. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115424 · Cited by 103
A hybrid approach for optimizing carbon footprint in intercloud environment
Justafort, V. D., Beaubrun, R., & Pierre, S. (2019) · IEEE Transactions on Services Computing · doi:10.1109/tsc.2016.2638900 · Cited by 7
Metadata
- Authors
- Liu, Z., Chen, Y., Bash, C., Wierman, A., Gmach, D., Wang, Z., Marwah, M., & Hyser, C.
- Venue
- ACM SIGMETRICS Performance Evaluation Review
- Published
- 2012-06-07
- Volume
- 40
- Issue
- 1
- Pages
- 175-186
- ISSN
- 0163-5999 (ISSN-L)
- OpenAlex
- W2997887534
- Cited by
- 176
- References
- 0
- FWCI
- 34.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Renewable and cooling aware workload management for sustainable data centers. https://app.cochat.ai/papers/10.1145/2318857.2254779
- The paper
- Liu, Z., Chen, Y., Bash, C., Wierman, A., Gmach, D., Wang, Z., Marwah, M., & Hyser, C. (2012). Renewable and cooling aware workload management for sustainable data centers. ACM SIGMETRICS Performance Evaluation Review. https://doi.org/10.1145/2318857.2254779
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.