Large-scale Internet applications, such as content distribution networks, are deployed across multiple datacenters and consume massive amounts of electricity. To provide uniformly low access latencies, these datacenters are geographically distributed and the deployment size at each location reflects the regional demand for the application. Consequently, an application's environmental impact can vary significantly depending on the geographical distribution of end-users, as electricity cost and carbon footprint per watt is location specific. In this paper, we describe FORTE: Flow Optimization based framework for request-Routing and Traffic Engineering. FORTE dynamically controls the fraction of user traffic directed to each datacenter in response to changes in both request workload and carbon footprint. It allows an operator to navigate the three-way tradeoff between access latency, carbon footprint, and electricity costs and to determine an optimal datacenter upgrade plan in response to increases in traffic load. We use FORTE to show that carbon taxes or credits are impractical in incentivizing carbon output reduction by providers of large-scale Internet applications. However, they can reduce carbon emissions by 10% without increasing the mean latency nor the electricity bill.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
US Environmental Protection Agency
(1998) · Choice Reviews Online · doi:10.5860/choice.35-4455 · Cited by 5,897
The Case for Energy-Proportional Computing
Barroso, L. A., & Hölzle, U. (2007) · Computer · doi:10.1109/mc.2007.443 · Cited by 2,491
The cost of a cloud: research problems in data center networks
Greenberg, A., Hamilton, J., Maltz, D. A., & Patel, P. (2008) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1496091.1496103 · Cited by 1,621
Worldwide electricity used in data centers
Koomey, J. G. (2008) · Environmental Research Letters · doi:10.1088/1748-9326/3/3/034008 · Cited by 972
(2010) · doi:10.5555/1855711.1855728 · Cited by 970
Cutting the electric bill for internet-scale systems
Qureshi, A., Weber, R., Balakrishnan, H., Guttag, J., & Maggs, B. (2009) · Proceedings of the ACM SIGCOMM 2009 conference on Data communication · doi:10.1145/1592568.1592584 · Cited by 830
The Akamai network: a platform for high-performance internet applications
Nygren, E., Sitaraman, R. K., & Sun, J. (2010) · ACM SIGOPS Operating Systems Review · doi:10.1145/1842733.1842736 · Cited by 726
Labovitz, C., Iekel-Johnson, S., McPherson, D., Oberheide, J., & Jahanian, F. (2010) · Proceedings of the ACM SIGCOMM 2010 conference · doi:10.1145/1851182.1851194 · Cited by 545
Rao, L., Liu, X., Xie, L., & Liu, W. (2010) · 2010 Proceedings IEEE INFOCOM · doi:10.1109/infcom.2010.5461933 · Cited by 526
Greening geographical load balancing
Liu, Z., Lin, M., Wierman, A., Low, S. H., & Andrew, L. L. H. (2011) · Proceedings of the ACM SIGMETRICS joint international conference on Measurement and modeling of computer systems · doi:10.1145/1993744.1993767 · Cited by 467
Dynamic right-sizing for power-proportional data centers
Lin, M., Wierman, A., Andrew, L. L. H., & Thereska, E. (2011) · 2011 Proceedings IEEE INFOCOM · doi:10.1109/infcom.2011.5934885 · Cited by 437
Greening the internet with nano data centers
Valancius, V., Laoutaris, N., Massoulié, L., Diot, C., & Rodriguez, P. (2009) · Proceedings of the 5th international conference on Emerging networking experiments and technologies · doi:10.1145/1658939.1658944 · Cited by 353
Williams, E. (2004) · Environmental Science & Technology · doi:10.1021/es035152j · Cited by 262
Robust and flexible power-proportional storage
Amur, H., Cipar, J., Gupta, V., Ganger, G. R., Kozuch, M. A., & Schwan, K. (2010) · Proceedings of the 1st ACM symposium on Cloud computing · doi:10.1145/1807128.1807164 · Cited by 195
Energy-aware load balancing in content delivery networks
Mathew, V., Sitaraman, R. K., & Shenoy, P. (2012) · 2012 Proceedings IEEE INFOCOM · doi:10.1109/infcom.2012.6195846 · Cited by 176
Capping the brown energy consumption of Internet services at low cost
Le, K., Bianchini, R., Nguyen, T. D., Bilgir, O., & Martonosi, M. (2010) · International Conference on Green Computing · doi:10.1109/greencomp.2010.5598305 · Cited by 173
NapSAC: design and implementation of a power-proportional web cluster
Krioukov, A., Mohan, P., Alspaugh, S., Keys, L., Culler, D., & Katz, R. H. (2010) · Proceedings of the first ACM SIGCOMM workshop on Green networking · doi:10.1145/1851290.1851294 · Cited by 171
Intelligent Placement of Datacenters for Internet Services
Goiri, Í., Le, K., Guitart, J., Torres, J., & Bianchini, R. (2011) · Proceedings of the ... International Conference on Distributed Computing Systems/Proceedings of the International Conference on Distributed Computing Systems · doi:10.1109/icdcs.2011.19 · Cited by 148
The energy and emergy of the internet
Raghavan, B., & Ma, J. (2011) · Proceedings of the 10th ACM Workshop on Hot Topics in Networks · doi:10.1145/2070562.2070571 · Cited by 92
Energy trade-offs among content delivery architectures
Feldmann, A., Gladisch, A., Kind, M., Lange, C., Smaragdakis, G., & Westphal, F.-J. (2010) · Conference on Telecommunication Techno-Economics (CTTE) · doi:10.1109/ctte.2010.5557700 · Cited by 51
Green server design: beyond operational energy to sustainability
Chang, J., Meza, J., Ranganathan, P., Bash, C. E., & Shah, A. J. (2010) · International Conference on Power aware computing and systems · Cited by 31
Cited by
Greening geographical load balancing
Liu, Z., Lin, M., Wierman, A., Low, S. H., & Andrew, L. L. H. (2011) · Proceedings of the ACM SIGMETRICS joint international conference on Measurement and modeling of computer systems · doi:10.1145/1993744.1993767 · Cited by 467
Zeng, D., Gu, L., Guo, S., Cheng, Z., & Yu, S. (2016) · IEEE Transactions on Computers · doi:10.1109/tc.2016.2536019 · Cited by 426
An Energy Efficient Ant Colony System for Virtual Machine Placement in Cloud Computing
Liu, X.-F., Zhan, Z.-H., Deng, J. D., Li, Y., Gu, T., & Zhang, J. (2018) · IEEE Transactions on Evolutionary Computation · doi:10.1109/tevc.2016.2623803 · Cited by 407
A Survey on Data Center Networking (DCN): Infrastructure and Operations
Xia, W., Zhao, P., Wen, Y., & Xie, H. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2016.2626784 · Cited by 267
Workflow scheduling in cloud: a survey
Wu, F., Wu, Q., & Tan, Y. (2015) · The Journal of Supercomputing · doi:10.1007/s11227-015-1438-4 · Cited by 260
Metadata
- Authors
- Gao, P. X., Curtis, A. R., Wong, B., & Keshav, S.
- Venue
- Proceedings of the ACM SIGCOMM 2012 conference on Applications, technologies, architectures, and protocols for computer communication
- Publisher
- ACM
- Published
- 2012-08-13
- Pages
- 211-222
- OpenAlex
- W1999971903
- Cited by
- 286
- References
- 21
- FWCI
- 49.54
- Type
- conference paper
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.