SpiroSmart: using a microphone to measure lung function on a mobile phone
Abstract
Home spirometry is gaining acceptance in the medical community because of its ability to detect pulmonary exacerbations and improve outcomes of chronic lung ailments. However, cost and usability are significant barriers to its widespread adoption. To this end, we present SpiroSmart, a low-cost mobile phone application that performs spirometry sensing using the built-in microphone. We evaluate SpiroSmart on 52 subjects, showing that the mean error when compared to a clinical spirometer is 5.1% for common measures of lung function. Finally, we show that pulmonologists can use SpiroSmart to diagnose varying degrees of obstructive lung ailments.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Various sensors such as camera sensor, microphone sensor, accelerometer sensor, and gyroscope sensor were used in healthcare-based applications.
“Various sensors such as camera sensor [53–55], microphone sensor [56–58], accelerometer sensor [59–61], and gyroscope sensor [59, 62] were used in the healthcare-based applications.”
From Applications of Artificial Intelligence and Big Data Analytics in m-Health: A Healthcare System Perspective (2020) · cites this paper as [56]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 43 · Cited by 245
- Authors
- Larson, E. C., Goel, M., Boriello, G., Heltshe, S., Rosenfeld, M., & Patel, S. N.
- Affiliations
- University of Washington (US)
- University of Washington, Seattle, WA
- Seattle Children's Hospital (US)
- Venue
- Proceedings of the 2012 ACM Conference on Ubiquitous Computing
- Publisher
- ACM
- Published
- 2012-09-05
- Pages
- 280-289
- OpenAlex
- W2126423656
- Cited by
- 245
- References
- 43
- Citations by year
- 2026: 9 · 2025: 26 · 2024: 10 · 2023: 21 · 2022: 24 · 2021: 30 · 2020: 27 · 2019: 20 · 2018: 14 · 2017: 11 · 2016: 15 · 2015: 21 · 2014: 9 · 2013: 7 · 2012: 1
- FWCI
- 64.27
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- home spirometry, mobile application, obstructive lung disease, telemedicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review