Experience report: functional programming of mHealth applications
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
A modular framework for the development of medical applications that promotes deterministic, robust and correct code is presented. The system is based on the portable Gambit Scheme programming language and provides a flexible cross-platform environment for developing graphical applications on mobile devices as well as medical instrumentation interfaces running on embedded platforms. Real world applications of this framework for mobile diagnostics, telemonitoring and automated drug infusions are reported. The source code for the core framework is open source and available at: https://github.com/part-cw/lambdanative.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Harris, P. A., Taylor, R., Thielke, R., Payne, J., Gonzalez, N., & Conde, J. G. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.08.010 · Cited by 51,384 · cited 1×
“The data is stored locally in an encrypted database and whenever network access is available the data is sent to a secure Research Electronic Data Capture (REDCap) [10] server via the REDCap application programming interface.”
The BSD packet filter: a new architecture for user-level packet capture
McCanne, S., & Jacobson, V. L. (1993) · Cited by 885
von Dadelszen, P., Payne, B., Li, J., Ansermino, J. M., Pipkin, F. B., Côté, A.-M., Douglas, M. J., Gruslin, A., Hutcheon, J. A., Joseph, K., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(10)61351-7 · Cited by 586
Revised 5 report on the algorithmic language scheme
Adams, N. I., Bartley, D. H., Brooks, G., Dybvig, R. K., Friedman, D. P., Halstead, R., Hanson, C., Haynes, C. T., Kohlbecker, E., Oxley, D., et al. (1998) · ACM SIGPLAN Notices · doi:10.1145/290229.290234 · Cited by 317
Johnson, S. C., & Hill, M. G. (1978) · Cited by 280
Prediction of Pneumonia in a Pediatric Emergency Department
Neuman, M. I., Monuteaux, M. C., Scully, K. J., & Bachur, R. G. (2011) · PEDIATRICS · doi:10.1542/peds.2010-3367 · Cited by 133 · cited 1×
“This is a critically important tool for continuous monitoring of oxygen saturation (SpO 2 ) in the operating room (OR), and is also a good predictor of disease severity and treatment response in a wide range of diseases such as pneumonia in children [7].”
Modern OpenGL: its design and evolution
Kilgard, M. J., & Akeley, K. (2008) · SIGGRAPH Asia Courses · doi:10.1145/1508044.1508092 · Cited by 10 · cited 1×
“Another common denominator between most modern computing platforms is the presence of an accelerated OpenGL or OpenGL ES graphics engine [5].”
Soltesz, K., van Heusden, K., Dumont, G. A., Hägglund, T. J., Petersen, C., West, N., & Ansermino, J. M. (2012) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000418552.16222.39 · Cited by 8
Self-citationWORLD CONGRESS OF ANESTHESIOLOGISTS 1955
&NA; (1955) · Anesthesia & Analgesia · doi:10.1213/00000539-195505000-00007 · Cited by 4
EQUIPMENT, MONITORING, AND ENGINEERING TECHNOLOGY
van Heusden, K., Dumont, G. A., Soltesz, K., Petersen, C., & West, N. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aer479 · Cited by 3
Self-citation
Research works printed but not linked: 7
- IEEE Standard for the Scheme Programming Language IEEE 1178-1990 ISBN: 1559371250 IEEE Standard for the Scheme Programming Language IEEE 1178-1990 ISBN: 1559371250
- Karlen W , Hudson J , Lim J , Petersen C , Anand R , Dumont GA , Ansermino JM. The Phone Oximeter . IEEE Engineering in Medicine and Biology Society Unconference , Boston, USA , August 30, 2011 Karlen W, Hudson J, Lim J, Petersen C, Anand R, Dumont GA, Ansermino JM. The Phone Oximeter. IEEE Engineering in Medicine and Biology Society Unconference, Boston, USA, August 30, 2011
- Dunsmuir D , Petersen C , Karlen W , Lim J , Dumont GA , Ansermino JM. The Phone Oximeter for Mobile Spot-Check. Society for Technology in Anesthesia 2012 Annual Meeting , Palm Beach, FL, USA , January 18-21, 2012 Dunsmuir D, Petersen C, Karlen W, Lim J, Dumont GA, Ansermino JM. The Phone Oximeter for Mobile Spot-Check. Society for Technology in Anesthesia 2012 Annual Meeting, Palm Beach, FL, USA, January 18-21, 2012
- Gorges M , Petersen C , Ansermino JM , Capturing vital signs for research in a multi-bed monitoring environment . Anesth Analg , 2011 , 113 (2S Suppl) , p. 42 Gorges M, Petersen C, Ansermino JM, Capturing vital signs for research in a multi-bed monitoring environment. Anesth Analg, 2011, 113 (2S Suppl), p. 42
- Görges M , Ansermino JM. Development of a Mobile Monitoring and Communications Solution for Anesthesia Team Members . Anesth Analg , 2011 , 112 (5S Suppl) , p. S207 Görges M, Ansermino JM. Development of a Mobile Monitoring and Communications Solution for Anesthesia Team Members. Anesth Analg, 2011, 112 (5S Suppl), p. S207
- Dumont G , Liu N , Petersen C , Chazot T , Fischler M. Closed- Loop Administration of Propofol Guided by the NeuroSense: Clinical Evaluation Using Robust Proportional-Integral-Derivative Design . American Society of Anesthesiologists (ASA) Annual Meeting 2011 Dumont G, Liu N, Petersen C, Chazot T, Fischler M. Closed- Loop Administration of Propofol Guided by the NeuroSense: Clinical Evaluation Using Robust Proportional-Integral-Derivative Design. American Society of Anesthesiologists (ASA) Annual Meeting 2011
- West N , Dumont GA , van Heusden K , Khosravi S , Petersen C , Ansermino JM. The administration of closed-loop control of anesthesia for gastrointestinal endoscopic investigations in children . Society for Pediatric Anesthesia AAP Pediatric Anesthesiology Annual Meeting , Tampa, FL, USA , February 23-26, 2012 West N, Dumont GA, van Heusden K, Khosravi S, Petersen C, Ansermino JM. The administration of closed-loop control of anesthesia for gastrointestinal endoscopic investigations in children. Society for Pediatric Anesthesia AAP Pediatric Anesthesiology Annual Meeting, Tampa, FL, USA, February 23-26, 2012
Cited by
Development of mHealth Applications for Pre-Eclampsia Triage
Dunsmuir, D. T., Payne, B. A., Cloete, G., Petersen, C. L., Gorges, M., Lim, J., von Dadelszen, P., Dumont, G. A., & Mark Ansermino, J. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2301156 · Cited by 87
“tions for Android or iOS operating systems [8].”
BackgroundSelf-citationKarlen, W., Gan, H., Chiu, M., Dunsmuir, D., Zhou, G., Dumont, G. A., & Ansermino, J. M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099266 · Cited by 85
“The application was built using a software framework that allows cross-platform development for medical applications [13].”
MethodSelf-citationAuditory deep sleep stimulation in older adults at home: a randomized crossover trial
Lustenberger, C., Ferster, M. L., Huwiler, S., Brogli, L., Werth, E., Huber, R., & Karlen, W. (2022) · Communications Medicine · doi:10.1038/s43856-022-00096-6 · Cited by 78
Usability and Feasibility of PIERS on the Move: An mHealth App for Pre-Eclampsia Triage
Lim, J., Cloete, G., Dunsmuir, D. T., Payne, B. A., Scheffer, C., von Dadelszen, P., Dumont, G. A., & Ansermino, J. M. (2015) · JMIR mHealth and uHealth · doi:10.2196/mhealth.3942 · Cited by 73
Self-citationExtending the framework for mobile health information systems Research: A content analysis
Miah, S. J., Gammack, J. G., & Hasan, N. (2017) · Information Systems · doi:10.1016/j.is.2017.04.001 · Cited by 69
Fröhlich, S., Helbling, M., Fucentese, S. F., Karlen, W., Frey, W. O., & Spörri, J. (2020) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-020-06110-5 · Cited by 46
m-Health: Lessons Learned by m-Experiences
Bravo, J., Hervás, R., Fontecha, J., & Gónzalez, I. (2018) · Sensors · doi:10.3390/s18051569 · Cited by 42
“Petersen et al. [41] study a modular framework with m-Health applications.”
BackgroundEnglish, L. L., Dunsmuir, D., Kumbakumba, E., Ansermino, J. M., Larson, C. P., Lester, R., Barigye, C., Ndamira, A., Kabakyenga, J., & Wiens, M. O. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.5167 · Cited by 40
“The prototype PARA app was then built as script within the LNhealth platform, which was developed using Lambda Native, a cross-platform open-source development environment [12,13].”
Self-citationHartinger, S. M., Martínez, N. N., Hattendorf, J., Verástegui, H., Karlen, W., Ortiz, M., & Mäusezahl, D. (2020) · BMC Medical Research Methodology · doi:10.1186/s12874-020-00950-y · Cited by 34
Developing mHealth Apps with Researchers: Multi-Stakeholder Design Considerations
Craven, M. P., Lang, A. R., & Martin, J. L. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-07635-5_2 · Cited by 27
“However, they accept that the use of Scheme will present a learning curve for engineering and the medical community personnel and that this had been the biggest challenge in their work so far (their development team consisted of four code developers on staff; one programmer, two physicists and one engineer, with diver…”
BackgroundRaihana, S., Dunsmuir, D. T., Huda, T. M., Zhou, G., Rahman, Q. S.-U., Garde, A., Moinuddin, M., Karlen, W., Dumont, G. A., Kissoon, N. “., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143213 · Cited by 17
“This application was built using Lambda Native [19], a cross-platform open-source development environment written in Scheme.”
MethodSelf-citationZhang, J., Tüshaus, L., Martínez, N. N., Moreo, M., Verástegui, H., Hartinger, S. M., Mäusezahl, D., & Karlen, W. (2018) · JMIR mhealth and uhealth · doi:10.2196/11896 · Cited by 11
“During the weekly visits, FWs filled out a CRF and recorded physiological measurements with an mHealth app developed with LambdaNative (University of British Columbia, Canada) [22].”
Görges, M., West, N., Petersen, C. L., & Ansermino, J. M. (2019) · JMIR Perioperative Medicine · doi:10.2196/13559 · Cited by 11
Self-citationTüshaus, L., Moreo, M., Zhang, J., Hartinger, S. M., Mäusezahl, D., & Karlen, W. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00478.2018 · Cited by 11
Multiple Patient Monitoring in the Operating Room using a Head-Mounted Display
Schlosser, P. D., Grundgeiger, T., & Happel, O. (2018) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3170427.3188460 · Cited by 10
Görges, M., Dumont, G. A., Petersen, C. L., & Ansermino, J. M. (2014) · International Conference on the Internet of Things (IoT) · doi:10.1109/iot.2014.7030114 · Cited by 7
Self-citationA Scheme-Based Closed-Loop Anesthesia System
Petersen, C. L., Görges, M., Ansermino, J. M., & Dumont, G. A. (2014) · doi:10.1145/2635648.2635651 · Cited by 4
Self-citationRaihana, S., Dunsmuir, D. T., Huda, T. M., Zhou, G., Rahman, Q. S.-U., Garde, A., Moinuddin, M., Karlen, W., Dumont, G. A., Kissoon, N. “., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0147560 · Cited by 4
Self-citationMHealth application for cancer care delivery
Üğüdücü, K., Cerit, T., Toprak, A. G., & Alankuş, G. (2024) · AIP conference proceedings · doi:10.1063/5.0194462 · Cited by 1
Metadata
- Authors
- Petersen, C. L., Gorges, M., Dunsmuir, D., Ansermino, M., & Dumont, G. A.
- Affiliations
- University of British Columbia (CA)
- University of British Columbia, Vancouver, BC, Canada
- Venue
- Proceedings of the 18th ACM SIGPLAN international conference on Functional programming
- Publisher
- ACM
- Published
- 2013-09-25
- Pages
- 357-362
- OpenAlex
- W2127102251
- Cited by
- 18
- References
- 10
- Citations by year
- 2024: 1 · 2022: 1 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 1 · 2016: 1 · 2015: 2 · 2014: 5
- FWCI
- 1.72
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- ACM SIGPLAN International Conference on Functional Programming (ICFP) (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Software › Logic, programming, and type systems
- Physical Sciences › Computer Science › Information Systems › Mobile and Web Applications
- Physical Sciences › Engineering › Control and Systems Engineering › Embedded Systems and FPGA Design
- Keywords
- medical software development, modular software framework, deterministic codes, embedded systems, mobile devices, graphical user interface, mobile diagnostics, remote patient monitoring, open source software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.