The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Occupancy Detection from Electricity Consumption Data
Abstract
Detecting when a household is occupied by its residents is fundamental to enable a number of home automation applications. Current systems for occupancy detection usually require the installation of dedicated sensors, like passive infrared sensors, magnetic reed switches, or cameras. In this paper, we investigate the suitability of digital electricity meters -- which are already available in millions of households worldwide -- to be used as occupancy sensors. To this end, we have collected fine-grained electricity consumption data along with ground-truth occupancy information for 5 households during a period of about 8 months. Our results show that using common classification methods it is possible to achieve occupancy detection accuracies of more than 80%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Comparison of the predicted and observed secondary structure of T4 phage lysozyme
Matthews, B. W. (1975) · Biochimica et Biophysica Acta (BBA) - Protein Structure · doi:10.1016/0005-2795(75)90109-9 · Cited by 5,399 · cited 1×
“For this reason we computed the Matthews correlation coefficient (MCC) over the results of our classifiers [15].”
MethodIs disaggregation the holy grail of energy efficiency? The case of electricity
Carrie Armel, K., Gupta, A., Shrimali, G., & Albert, A. (2013) · Energy Policy · doi:10.1016/j.enpol.2012.08.062 · Cited by 595
Cited by
Himeur, Y., Ghanem, K., Alsalemi, A., Bensaali, F., & Amira, A. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.116601 · Cited by 660
Candanedo, L. M., & Feldheim, V. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.071 · Cited by 586
Building occupancy estimation and detection: A review
Chen, Z., Jiang, C., & Xie, L. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.03.084 · Cited by 280
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
Survey of Non-Image-Based Approaches for Counting People
Kouyoumdjieva, S. T., Danielis, P., & Karlsson, G. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2902824 · Cited by 61
Metadata
- Authors
- Kleiminger, W., Beckel, C., Staake, T., & Santini, S.
- Venue
- Proceedings of the 5th ACM Workshop on Embedded Systems For Energy-Efficient Buildings
- Publisher
- ACM
- Published
- 2013-11-11
- Pages
- 1-8
- OpenAlex
- W2069872789
- Cited by
- 247
- References
- 3
- FWCI
- 13.01
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Occupancy Detection from Electricity Consumption Data. https://app.cochat.ai/papers/10.1145/2528282.2528295
- The paper
- Kleiminger, W., Beckel, C., Staake, T., & Santini, S. (2013). Occupancy Detection from Electricity Consumption Data. Proceedings of the 5th ACM Workshop on Embedded Systems For Energy-Efficient Buildings. https://doi.org/10.1145/2528282.2528295
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.