A measurement-based analysis of the energy consumption of data center servers
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Energy consumption is a growing issue in data centers, impacting their economic viability and their public image. In this work we empirically characterize the power and energy consumed by different types of servers. In particular, in order to understand the behavior of their energy and power consumption, we perform measurements in different servers. In each of them, we exhaustively measure the power consumed by the CPU, the disk, and the network interface under different configurations, identifying the optimal operational levels. One interesting conclusion of our study is that the curve that defines the minimal CPU power as a function of the load is neither linear nor purely convex as has been previously assumed. Moreover, we find that the efficiency of the various server components can be maximized by tuning the CPU frequency and the number of active cores as a function of the system and network load, while the block size of I/O operations should be always maximized by applications. We also show how to estimate the energy consumed by an application as a function of some simple parameters, like the CPU load, and the disk and network activity. We validate the proposed approach by accurately estimating the energy of a map-reduce computation in a Hadoop platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trends in worldwide ICT electricity consumption from 2007 to 2012
Van Heddeghem, W., Lambert, S., Lannoo, B., Colle, D., Pickavet, M., & Demeester, P. (2014) · Computer Communications · doi:10.1016/j.comcom.2014.02.008 · Cited by 533 · cited 1×
“According to Van Hed-deghem and Lambert [8], data centers’ total energy consumption in 2012 was about 270 TWh , which corresponds to almost 2% of the global electricity consumption, and has an approximated annual growth rate of 4 .”
MethodRaghavendra (2008) · doi:10.1145/1353534.1346289 · Cited by 134
Cited by
On Global Electricity Usage of Communication Technology: Trends to 2030
Andrae, A., & Edler, T. (2015) · Challenges · doi:10.3390/challe6010117 · Cited by 1,334
Data Center Energy Consumption Modeling: A Survey
Dayarathna, M., Wen, Y., & Fan, R. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2481183 · Cited by 1,165
Rapid and accurate energy models through calibration with IPMI and RAPL
Kavanagh, R., & Djemame, K. (2019) · Concurrency and Computation: Practice and Experience · doi:10.1002/cpe.5124 · Cited by 23
Metadata
- Authors
- Arjona Aroca, J., Chatzipapas, A., Fernández Anta, A., & Mancuso, V.
- Venue
- Proceedings of the 5th international conference on Future energy systems
- Publisher
- ACM
- Published
- 2014-06-11
- Pages
- 63-74
- OpenAlex
- W2071544756
- Cited by
- 51
- References
- 2
- FWCI
- 6.62
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A measurement-based analysis of the energy consumption of data center servers. https://app.cochat.ai/papers/10.1145/2602044.2602061
- The paper
- Arjona Aroca, J., Chatzipapas, A., Fernández Anta, A., & Mancuso, V. (2014). A measurement-based analysis of the energy consumption of data center servers. Proceedings of the 5th international conference on Future energy systems. https://doi.org/10.1145/2602044.2602061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.