The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
WristFlex: low-power gesture input with wrist-worn pressure sensors
Open accessAbstract
In this paper we present WristFlex, an always-available on-body gestural interface. Using an array of force sensitive resistors (FSRs) worn around the wrist, the interface can distinguish subtle finger pinch gestures with high accuracy (>80 %) and speed. The system is trained to classify gestures from subtle tendon movements on the wrist. We demonstrate that WristFlex is a complete system that works wirelessly in real-time. The system is simple and light-weight in terms of power consumption and computational overhead. WristFlex's sensor power consumption is 60.7 uW, allowing the prototype to potentially last more then a week on a small lithium polymer battery. Also, WristFlex is small and non-obtrusive, and can be integrated into a wristwatch or a bracelet. We perform user studies to evaluate the accuracy, speed, and repeatability. We demonstrate that the number of gestures can be extended with orientation data from an accelerometer. We conclude by showing example applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The WEKA data mining software: an update
Hall, M., Frank, E., Holmes, G., Pfahringer, B., Reutemann, P., & Witten, I. H. (2009) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1656274.1656278 · Cited by 17,750
Cited by
Tomo: Wearable, Low-Cost Electrical Impedance Tomography for Hand Gesture Recognition
Zhang, Y., & Harrison, C. (2015) · Proceedings of the 28th Annual ACM Symposium on User Interface Software & Technology · doi:10.1145/2807442.2807480 · Cited by 283
FingerPing: Recognizing Fine-grained Hand Poses using Active Acoustic On-body Sensing
Zhang, C., Xue, Q., Waghmare, A., Meng, R., Jain, S., Han, Y., Li, X., Cunefare, K., Ploetz, T., Starner, T., et al. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3174011 · Cited by 82
Fusion of Wearable and Contactless Sensors for Intelligent Gesture Recognition
Liang, X., Li, H., Wang, W., Liu, Y., Ghannam, R., Fioranelli, F., & Heidari, H. (2019) · Advanced Intelligent Systems · doi:10.1002/aisy.201900088 · Cited by 64
Song, X., van de Ven, S. S., Chen, S., Kang, P., Gao, Q., Jia, J., & Shull, P. B. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.811950 · Cited by 47
WristDial: An Eyes-Free Integer-Value Input Method by Quantizing the Wrist Rotation
Youn, E., Lee, S., Kim, S., Shim, Y. A., Chan, L., & Lee, G. (2021) · International Journal of Human–Computer Interaction · doi:10.1080/10447318.2021.1898848 · Cited by 10
Metadata
- Authors
- Dementyev, A., & Paradiso, J. A.
- Venue
- Proceedings of the 27th annual ACM symposium on User interface software and technology
- Publisher
- ACM
- Published
- 2014-10-05
- Pages
- 161-166
- OpenAlex
- W2008834805
- Cited by
- 203
- References
- 1
- FWCI
- 16.46
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: WristFlex: low-power gesture input with wrist-worn pressure sensors. https://app.cochat.ai/papers/10.1145/2642918.2647396
- The paper
- Dementyev, A., & Paradiso, J. A. (2014). WristFlex: low-power gesture input with wrist-worn pressure sensors. Proceedings of the 27th annual ACM symposium on User interface software and technology. https://doi.org/10.1145/2642918.2647396
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.