The DOI matches its Crossref record.
Advancing Muscle-Computer Interfaces with High-Density Electromyography
Abstract
In this paper we present our results on using electromyographic (EMG) sensor arrays for finger gesture recognition. Sensing muscle activity allows to capture finger motion without placing sensors directly at the hand or fingers and thus may be used to build unobtrusive body-worn interfaces. We use an electrode array with 192 electrodes to record a high-density EMG of the upper forearm muscles. We present in detail a baseline system for gesture recognition on our dataset, using a naive Bayes classifier to discriminate the 27 gestures. We recorded 25 sessions from 5 subjects. We report an average accuracy of 90% for the within-session scenario, showing the feasibility of the EMG approach to discriminate a large number of subtle gestures. We analyze the effect of the number of used electrodes on the recognition performance and show the benefit of using high numbers of electrodes. Cross-session recognition typically suffers from electrode position changes from session to session. We present two methods to estimate the electrode shift between sessions based on a small amount of calibration data and compare it to a baseline system with no shift compensation. The presented methods raise the accuracy from 59% baseline accuracy to 75% accuracy after shift compensation. The dataset is publicly available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Tomo: Wearable, Low-Cost Electrical Impedance Tomography for Hand Gesture Recognition
Zhang, Y., & Harrison, C. (2015) · Proceedings of the 28th Annual ACM Symposium on User Interface Software & Technology · doi:10.1145/2807442.2807480 · Cited by 283
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
Ni, S., Al-qaness, M. A. A., Hawbani, A., Al-Alimi, D., Abd Elaziz, M., & Ewees, A. A. (2024) · Applied Soft Computing · doi:10.1016/j.asoc.2024.112235 · Cited by 74
Bio-signal based elbow angle and torque simultaneous prediction during isokinetic contraction
Zhou, Y., Liu, J., Zeng, J., Li, K., & Liu, H. (2019) · Science China Technological Sciences · doi:10.1007/s11431-018-9354-5 · Cited by 30
Metadata
- Authors
- Amma, C., Krings, T., Böer, J., & Schultz, T.
- Venue
- Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems
- Publisher
- ACM
- Published
- 2015-04-18
- Pages
- 929-938
- OpenAlex
- W2004931716
- Cited by
- 168
- References
- 0
- FWCI
- 21.67
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advancing Muscle-Computer Interfaces with High-Density Electromyography. https://app.cochat.ai/papers/10.1145/2702123.2702501
- The paper
- Amma, C., Krings, T., Böer, J., & Schultz, T. (2015). Advancing Muscle-Computer Interfaces with High-Density Electromyography. Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems. https://doi.org/10.1145/2702123.2702501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.