SkinTrack: Using the Body as an Electrical Waveguide for Continuous Finger Tracking on the Skin
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
SkinTrack is a wearable system that enables continuous touch tracking on the skin. It consists of a ring, which emits a continuous high frequency AC signal, and a sensing wristband with multiple electrodes. Due to the phase delay inherent in a high-frequency AC signal propagating through the body, a phase difference can be observed between pairs of electrodes. SkinTrack measures these phase differences to compute a 2D finger touch coordinate. Our approach can segment touch events at 99% accuracy, and resolve the 2D location of touches with a mean error of 7.6mm. As our approach is compact, non-invasive, low-cost and low-powered, we envision the technology being integrated into future smartwatches, supporting rich touch interactions beyond the confines of the small touchscreen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The WEKA data mining software: an update
Hall, M., Frank, E., Holmes, G., Pfahringer, B., Reutemann, P., & Witten, I. H. (2009) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1656274.1656278 · Cited by 17,750
Cited by
FingerPing: Recognizing Fine-grained Hand Poses using Active Acoustic On-body Sensing
Zhang, C., Xue, Q., Waghmare, A., Meng, R., Jain, S., Han, Y., Li, X., Cunefare, K., Ploetz, T., Starner, T., et al. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3174011 · Cited by 82
“Thus, rings built with different sensing modalities have been explored to classify finger gestures, such as acoustic and motion sensing [21, 22], computer vision [2] , magnetic sensing [3, 10], or electrical sensing [24].”
BackgroundThe sense of agency in emerging technologies for human–computer integration: A review
Cornelio, P., Haggard, P., Hornbaek, K., Georgiou, O., Bergström, J., Subramanian, S., & Obrist, M. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.949138 · Cited by 75
Design Guideline for Developing Safe Systems that Apply Electricity to the Human Body
Kono, M., Takahashi, T., Nakamura, H., Miyaki, T., & Rekimoto, J. (2018) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3184743 · Cited by 63
Metadata
- Authors
- Zhang, Y., Zhou, J., Laput, G., & Harrison, C.
- Venue
- Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems
- Publisher
- ACM
- Published
- 2016-05-07
- Pages
- 1491-1503
- OpenAlex
- W2400840826
- Cited by
- 139
- References
- 1
- FWCI
- 14.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SkinTrack: Using the Body as an Electrical Waveguide for Continuous Finger Tracking on the Skin. https://app.cochat.ai/papers/10.1145/2858036.2858082
- The paper
- Zhang, Y., Zhou, J., Laput, G., & Harrison, C. (2016). SkinTrack: Using the Body as an Electrical Waveguide for Continuous Finger Tracking on the Skin. Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems. https://doi.org/10.1145/2858036.2858082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.