Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

FallDeFi: Ubiquitous Fall Detection using Commodity Wi-Fi Devices

Palipana, Sameera, Rojas, David, Agrawal, Piyush, Pesch, Dirk·2018·Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies

Abstract

Falling or tripping among elderly people living on their own is recognized as a major public health worry that can even lead to death. Fall detection systems that alert caregivers, family members or neighbours can potentially save lives. In the past decade, an extensive amount of research has been carried out to develop fall detection systems based on a range of different detection approaches, i.e, wearable and non-wearable sensing and detection technologies. In this paper, we consider an emerging non-wearable fall detection approach based on WiFi Channel State Information (CSI). Previous CSI based fall detection solutions have considered only time domain approaches. Here, we take an altogether different direction, time-frequency analysis as used in radar fall detection. We use the conventional Short-Time Fourier Transform (STFT) to extract time-frequency features and a sequential forward selection algorithm to single out features that are resilient to environment changes while maintaining a higher fall detection rate. When our system is pre-trained, it has a 93% accuracy and compared to RTFall and CARM, this is a 12% and 15% improvement respectively. When the environment changes, our system still has an average accuracy close to 80% which is more than a 20% to 30% and 5% to 15% improvement respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/3161183

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Research works printed but not linked: 13

  1. 10.1109/ACSSC.2016.7869686 · doi:10.1109/acssc.2016.7869686
  2. 10.1136/ip.9.1.93-a · doi:10.1136/ip.9.1.93-a
  3. 10.1109/MASS.2012.6502524 · doi:10.1109/mass.2012.6502524
  4. 10.1109/PIMRC.2013.6666749 · doi:10.1109/pimrc.2013.6666749
  5. Chi Zicheng, 2016, IEEE 24th Int. Conf. on Network Protocols (ICNP), 1
  6. Gadde Ajay, 2014, SPIE Defense+ Security, 907712
  7. 10.1109/ChinaSIP.2014.6889337 · doi:10.1109/chinasip.2014.6889337
  8. Erol Baris, 2075, Signal Processing Conference (EUSIPCO), 2016
  9. 10.1109/PIMRC.2013.6666753 · doi:10.1109/pimrc.2013.6666753
  10. Yan, 2014, Proc. of the 20th annual int. conf. on Mobile computing and networking (Mobicom), 617
  11. Erol Baris, 2016, SPIE Defense+ Security, 982918
  12. 10.1109/TSMCB.2007.902249 · doi:10.1109/tsmcb.2007.902249
  13. 10.1016/j.sigpro.2008.12.011 · doi:10.1016/j.sigpro.2008.12.011

Cited by

See all 279

Metadata

Authors
Palipana, S., Rojas, D., Agrawal, P., & Pesch, D.
Venue
Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Published
2018-01-08
Volume
1
Issue
4
Pages
1-25
ISSN
2474-9567 (ISSN-L)
OpenAlex
W2783857023
Cited by
279
References
33
FWCI
12.71
Type
journal article
Language
en
Open access
closed
Funders
  • United Technologies Research Centre, Cork, Ireland
  • Irish Research Council

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: FallDeFi: Ubiquitous Fall Detection using Commodity Wi-Fi Devices. https://app.cochat.ai/papers/10.1145/3161183
The paper
Palipana, S., Rojas, D., Agrawal, P., & Pesch, D. (2018). FallDeFi: Ubiquitous Fall Detection using Commodity Wi-Fi Devices. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies. https://doi.org/10.1145/3161183

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.