The DOI matches its Crossref record.
From Fresnel Diffraction Model to Fine-grained Human Respiration Sensing with Commodity Wi-Fi Devices
Abstract
Non-intrusive respiration sensing without any device attached to the target plays a particular important role in our everyday lives. However, existing solutions either require dedicated hardware or employ special-purpose signals which are not cost-effective, significantly limiting their real-life applications. Also very few work concerns about the theory behind and can explain the large performance variations in different scenarios. In this paper, we employ the cheap commodity Wi-Fi hardware already ubiquitously deployed around us for respiration sensing. For the first time, we utilize the Fresnel diffraction model to accurately quantify the relationship between the diffraction gain and human target's subtle chest displacement and thus successfully turn the previously considered "destructive" obstruction diffraction in the First Fresnel Zone (FFZ) into beneficial sensing capability. By not just considering the chest displacement at the frontside as the existing solutions, but also the subtle displacement at the backside, we achieve surprisingly matching results with respect to the theoretical plots and become the first to clearly explain the theory behind the performance distinction between lying and sitting for respiration sensing. With two cheap commodity Wi-Fi cards each equipped with just one antenna, we are able to achieve higher than 98% accuracy of respiration rate monitoring at more than 60% of the locations in the FFZ. Furthermore, we are able to present the detail heatmap of the sensing capability at each location inside the FFZ to guide the respiration sensing so users clearly know where are the good positions for respiration monitoring and if located at a bad position, how to move just slightly to reach a good position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
WiFi Sensing with Channel State Information: A Survey
Ma, Y., Zhou, G., & Wang, S. (2020) · ACM Computing Surveys · doi:10.1145/3310194 · Cited by 869
FarSense: Pushing the Range Limit of WiFi-based Respiration Sensing with CSI Ratio of Two Antennas
Zeng, Y., Wu, D., Xiong, J., Yi, E., Gao, R., & Zhang, D. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3351279 · Cited by 469
Self-citationTowards 3D human pose construction using wifi
Jiang, W., Xue, H., Miao, C., Wang, S., Lin, S., Tian, C., Murali, S., Hu, H., Sun, Z., & Su, L. (2020) · Proceedings of the 26th Annual International Conference on Mobile Computing and Networking · doi:10.1145/3372224.3380900 · Cited by 276
A Survey on Human Behavior Recognition Using Channel State Information
Wang, Z., Jiang, K., Hou, Y., Dou, W., Zhang, C., Huang, Z., & Guo, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2949123 · Cited by 149
Metadata
- Authors
- Zhang, F., Zhang, D., Xiong, J., Wang, H., Niu, K., Jin, B., & Wang, Y.
- Venue
- Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Published
- 2018-03-26
- Volume
- 2
- Issue
- 1
- Pages
- 1-23
- ISSN
- 2474-9567 (ISSN-L)
- OpenAlex
- W2794658983
- Cited by
- 185
- References
- 0
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: From Fresnel Diffraction Model to Fine-grained Human Respiration Sensing with Commodity Wi-Fi Devices. https://app.cochat.ai/papers/10.1145/3191785
- The paper
- Zhang, F., Zhang, D., Xiong, J., Wang, H., Niu, K., Jin, B., & Wang, Y. (2018). From Fresnel Diffraction Model to Fine-grained Human Respiration Sensing with Commodity Wi-Fi Devices. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies. https://doi.org/10.1145/3191785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.