The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
FullBreathe: Full Human Respiration Detection Exploiting Complementarity of CSI Phase and Amplitude of WiFi Signals
Abstract
Human respiration detection based on Wi-Fi signals does not require users to carry any device, hence it has drawn a lot of attention due to better user acceptance and great potential for real-world deployment. However, recent studies show that respiration sensing performance varies in different locations due to the nature of Wi-Fi radio wave propagation in indoor environments, i.e., respiration detection may experience poor performance at certain locations which we call "blind spots". In this paper, we aim to address the blind spot problem to ensure full coverage of respiration detection. Basically, the amplitude and phase of Wi-Fi channel state information (CSI) are orthogonal and complementary to each other, so they can be combined to eliminate the blind spots. However, accurate CSI phase cannot be obtained from commodity Wi-Fi due to the clock-unsynchronized transceivers. Thus, we apply conjugate multiplication (CM) of CSI between two antennas to remove the phase offset and construct two orthogonal signals--new "amplitude and phase" which are still complementary to each other. In this way, we can ensure full human respiration detection. Based on these ideas, We design and implement a real-time respiration detection system with commodity Wi-Fi devices. We conduct extensive experiments to validate our model and design. The results show that, with only one transceiver pair and without leveraging multiple sub-carriers, our system enables full location coverage with no blind spot, showing great potential for real deployment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding and Modeling of WiFi Signal Based Human Activity Recognition
Wang, W., Liu, A. X., Shahzad, M., Ling, K., & Lu, S. (2015) · Proceedings of the 21st Annual International Conference on Mobile Computing and Networking · doi:10.1145/2789168.2790093 · Cited by 1,110
Fine-grained sleep monitoring: Hearing your breathing with smartphones
Ren, Y., Wang, C., Yang, J., & Chen, Y. (2015) · 2015 IEEE Conference on Computer Communications (INFOCOM) · doi:10.1109/infocom.2015.7218494 · Cited by 119
Cited by
FarSense: Pushing the Range Limit of WiFi-based Respiration Sensing with CSI Ratio of Two Antennas
Zeng, Y., Wu, D., Xiong, J., Yi, E., Gao, R., & Zhang, D. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3351279 · Cited by 469
Self-citationA Survey on Human Behavior Recognition Using Channel State Information
Wang, Z., Jiang, K., Hou, Y., Dou, W., Zhang, C., Huang, Z., & Guo, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2949123 · Cited by 149
Metadata
- Authors
- Zeng, Y., Wu, D., Gao, R., Gu, T., & Zhang, D.
- Venue
- Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Published
- 2018-09-18
- Volume
- 2
- Issue
- 3
- Pages
- 1-19
- ISSN
- 2474-9567 (ISSN-L)
- OpenAlex
- W2891312406
- Cited by
- 224
- References
- 2
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FullBreathe: Full Human Respiration Detection Exploiting Complementarity of CSI Phase and Amplitude of WiFi Signals. https://app.cochat.ai/papers/10.1145/3264958
- The paper
- Zeng, Y., Wu, D., Gao, R., Gu, T., & Zhang, D. (2018). FullBreathe: Full Human Respiration Detection Exploiting Complementarity of CSI Phase and Amplitude of WiFi Signals. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies. https://doi.org/10.1145/3264958
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.