The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Integrated Microreactors for Reaction Automation: New Approaches to Reaction Development
Abstract
Applications of microsystems (microreactors) in continuous-flow chemistry have expanded rapidly over the past two decades, with numerous reports of higher conversions and yields compared to conventional batch benchtop equipment. Synthesis applications are enhanced by chemical information gained from integrating microreactor components with sensors, actuators, and automated fluid handling. Moreover, miniaturized systems allow experiments on well-defined samples at conditions not easily accessed by conventional means, such as reactions at high pressure and temperatures. The wealth of synthesis information that could potentially be acquired through use of microreactors integrated with physical sensors and analytical chemistry techniques for online reaction monitoring has not yet been well explored. The increased efficiency resulting from use of continuous-flow microreactor platforms to automate reaction screening and optimization encourages a shift from current batchwise chemical reaction development to this new approach. We review advances in this new area and provide application examples of online monitoring and automation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Cited by
The Hitchhiker’s Guide to Flow Chemistry
Plutschack, M. B., Pieber, B., Gilmore, K., & Seeberger, P. H. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00183 · Cited by 1,995
Cambié, D., Bottecchia, C., Straathof, N. J. W., Hessel, V., & Noël, T. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00707 · Cited by 1,502
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Flow Chemistry – A Key Enabling Technology for (Multistep) Organic Synthesis
Wegner, J., Ceylan, S., & Kirschning, A. (2012) · Advanced Synthesis & Catalysis · doi:10.1002/adsc.201100584 · Cited by 639
Continuous flow reactors: a perspective
Wiles, C., & Watts, P. (2012) · Green Chem. · doi:10.1039/c1gc16022b · Cited by 626
Metadata
- Authors
- McMullen, J. P., & Jensen, K. F.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2010-06-01
- Volume
- 3
- Issue
- 1
- Pages
- 19-42
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2135087371
- Cited by
- 359
- References
- 2
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrated Microreactors for Reaction Automation: New Approaches to Reaction Development. https://app.cochat.ai/papers/10.1146/annurev.anchem.111808.073718
- The paper
- McMullen, J. P., & Jensen, K. F. (2010). Integrated Microreactors for Reaction Automation: New Approaches to Reaction Development. Annual Review of Analytical Chemistry. https://doi.org/10.1146/annurev.anchem.111808.073718
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.