The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cochlear Implants: Some Likely Next Steps
Abstract
▪ Abstract The history of cochlear implants is marked by large improvements in performance, especially over the past two decades and especially due to the development of ever-better processing strategies. Although the progress to date has been substantial, present devices still do not restore normal speech reception, even for top performers and particularly for listening to speech in competition with noise or other talkers. In addition, a wide range of outcomes persists, with some patients receiving little benefit using the same devices that support high levels of speech reception for others. The purpose of this review is to describe some likely possibilities for further improvement, including (a) combined electric and acoustic stimulation of the auditory system for patients with significant residual hearing, (b) use of bilateral implants, (c) a closer replication with implants of the processing steps in the normal cochlea, and (d) applications of knowledge about factors that are correlated with outcomes to help patients presently at the low end of the performance scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Cited by
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Self-citationLi, N., Zhang, X., Song, Q., Su, R., Zhang, Q., Kong, T., Liu, L., Jin, G., Tang, M., & Cheng, G. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.065 · Cited by 428
Neural Stimulation with a Carbon Nanotube Microelectrode Array
Wang, K., Fishman, H. A., Dai, H., & Harris, J. S. (2006) · Nano Letters · doi:10.1021/nl061241t · Cited by 415
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Self-citation
Metadata
- Authors
- Wilson, B. S., Lawson, D. T., Müller, J. M., Tyler, R. S., & Kiefer, J.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2003-08
- Volume
- 5
- Issue
- 1
- Pages
- 207-249
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2108065075
- Cited by
- 160
- References
- 1
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cochlear Implants: Some Likely Next Steps. https://app.cochat.ai/papers/10.1146/annurev.bioeng.5.040202.121645
- The paper
- Wilson, B. S., Lawson, D. T., Müller, J. M., Tyler, R. S., & Kiefer, J. (2003). Cochlear Implants: Some Likely Next Steps. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev.bioeng.5.040202.121645
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.