SQUID-Detected Magnetic Resonance Imaging in Microtesla Fields
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The use of very low noise magnetometers based on Superconducting QUantum Interference Devices (SQUIDs) enables nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) in microtesla magnetic fields. An untuned superconducting flux transformer coupled to a SQUID achieves a magnetic field noise of 10(-15) T Hz(-1/2). The frequency-independent response of this magnetometer combined with prepolarization of the nuclear spins yields an NMR signal that is independent of the Larmor frequency omega0. An MRI system operating in a field of 132 microT, corresponding to a proton frequency of 5.6 kHz, achieves an in-plane resolution of 0.7 x 0.7 mm2 in phantoms. Measurements of the longitudinal relaxation time T1 in different concentrations of agarose gel over five decades of frequency reveal much greater T1-differentiation at fields below a few millitesla. Microtesla MRI has the potential to image tumors with substantially greater T1-weighted contrast than is achievable in high fields in the absence of a contrast agent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Principles of Magnetic Resonance
Slichter, C. P. (1990) · Springer Series in Solid-State Sciences · doi:10.1007/978-3-662-09441-9 · Cited by 5,520
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
SQUID‐detected MRI at 132 μT with T1‐weighted contrast established at 10 μT–300 mT
Lee, S. K., Möβle, M., Myers, W., Kelso, N., Trabesinger, A. H., Pines, A., & Clarke, J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20316 · Cited by 139
Self-citationNuclear magnetic resonance in the nanoTesla range
Burghoff, M., Hartwig, S., Trahms, L., & Bernarding, J. (2005) · Applied Physics Letters · doi:10.1063/1.2006981 · Cited by 101
Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields
Volegov, P., Matlachov, A. N., Espy, M. A., George, J. S., & Kraus, R. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20193 · Cited by 80
Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device
Schlenga, K., McDermott, R., Clarke, J., de Souza, R. E., Wong-Foy, A., & Pines, A. (1999) · Applied Physics Letters · doi:10.1063/1.125432 · Cited by 67
Self-citationSQUID-Detected in vivo MRI at Microtesla Magnetic Fields
Moszligle, M., Myers, W. R., Lee, S.-K., Kelso, N., Hatridge, M., Pines, A., & Clarke, J. (2005) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/tasc.2005.850043 · Cited by 55
Self-citation
Cited by
Sarracanie, M., LaPierre, C. D., Salameh, N., Waddington, D. E. J., Witzel, T., & Rosen, M. S. (2015) · Scientific Reports · doi:10.1038/srep15177 · Cited by 295
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“The limit of detectivity of the dc SQUID can be of the order of 1 fT/ √ Hz [45–47] in a frequency range of magnetic field from dc to GHz [48].”
Background
Metadata
- Authors
- Clarke, J., Hatridge, M., & Mößle, M.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2007-08-15
- Volume
- 9
- Issue
- 1
- Pages
- 389-413
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2141578509
- Cited by
- 205
- References
- 9
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.