Mass Spectrometry as a Tool for Protein Crystallography
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
▪ Abstract Atomic resolution structure determinations of proteins by X-ray crystallography are formidable multidisciplinary undertakings, requiring protein construct design, expression and purification, crystallization trials, phase determination, and model building. Modern mass spectrometric methods can greatly facilitate these obligate tasks. Thus, mass spectrometry can be used to verify that the desired protein construct has been correctly expressed, to define compact domains in the target protein, to assess the components contained within the protein crystals, and to screen for successful incorporation of seleno-methionine and other heavy metal reagents used for phasing. In addition, mass spectrometry can be used to address issues of modeling, topology, and side-chain proximity. Here, we demonstrate how rational use of mass spectrometry assists and expedites high resolution X-ray structure determination through each stage of the process of protein crystallography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Self-citationCovey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Vinkemeier, U., Cohen, S. L., Moarefi, I., Chait, B. T., Kuriyan, J., & Darnell, J. E. (1996) · The EMBO Journal · doi:10.1002/j.1460-2075.1996.tb00946.x · Cited by 308
Self-citation
Cited by
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Crystal structure and mechanism of a calcium-gated potassium channel
Jiang, Y., Lee, A., Chen, J., Cadene, M., Chait, B. T., & MacKinnon, R. (2002) · Nature · doi:10.1038/417515a · Cited by 1,332
Self-citationMembrane protein crystallization
Caffrey, M. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(03)00043-1 · Cited by 340
Jiang, Y., Pico, A., Cadene, M., Chait, B. T., & MacKinnon, R. (2001) · Neuron · doi:10.1016/s0896-6273(01)00236-7 · Cited by 300
Self-citationRationalizing membrane protein overexpression
Wagner, S., Bader, M. L., Drew, D., & de Gier, J.-W. (2006) · Trends in Biotechnology · doi:10.1016/j.tibtech.2006.06.008 · Cited by 270
Metadata
- Authors
- Cohen, S. L., & Chait, B. T.
- Venue
- Annual Review of Biophysics and Biomolecular Structure
- Publisher
- Annual Reviews
- Published
- 2001-06
- Volume
- 30
- Issue
- 1
- Pages
- 67-85
- ISSN
- 1056-8700 (ISSN-L)
- 1545-4266
- OpenAlex
- W2096844618
- Cited by
- 63
- References
- 3
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass Spectrometry as a Tool for Protein Crystallography. https://app.cochat.ai/papers/10.1146/annurev.biophys.30.1.67
- The paper
- Cohen, S. L., & Chait, B. T. (2001). Mass Spectrometry as a Tool for Protein Crystallography. Annual Review of Biophysics and Biomolecular Structure. https://doi.org/10.1146/annurev.biophys.30.1.67
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.