The DOI matches its Crossref record.
Voltage Dependence of the Na-K Pump
Abstract
Present evidence demonstrates that the Na-K pump rate is voltage dependent, whereas early work was largely inconclusive. The I-V relationship has a positive slope over a wide voltage range, and the existence of a negative slope region is now doubtful. Monotonic voltage dependence is consistent with the reaction cycle containing a single voltage-dependent step. Recent measurements suggest that this voltage-dependent step occurs during Na translocation and may be deocclusion of Na+. In addition, two results suggest that K translocation is voltage insensitive: (a) large positive potentials appear to have no influence on Rb-Rb exchange or associated conformational transitions; and (b) transient currents associated with Na translocation appear to involve movement of a single charge, which is sufficient for a 3Na-2K cycle. The simplest interpretation is that the pump's cation binding sites supply two negative charges. Pre-steady-state measurements demonstrate that Na translocation precedes the pump cycle's rate-limiting step, presumably K translocation. But, because K translocation seems voltage insensitive, the voltage dependence of the steady-state pump rate probably reflects that of the concentration of the intermediate entering this slow step. Further pump current and flux data (both transient and steady-state), carefully determined over a range of conditions, should increase our understanding of the voltage-dependent step(s) in the Na-K pump cycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biowire: a platform for maturation of human pluripotent stem cell–derived cardiomyocytes
Nunes, S. S., Miklas, J. W., Liu, J., Aschar-Sobbi, R., Xiao, Y., Zhang, B., Jiang, J., Massé, S., Gagliardi, M., Hsieh, A., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2524 · Cited by 952
Lingrel, J. B., & Kuntzweiler, T. (1994) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)32067-7 · Cited by 744
Structural organization, ion transport, and energy transduction of P-type ATPases
Møller, J. V., Juul, B., & le Maire, M. (1996) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(95)00017-8 · Cited by 736
Skou, J. C., & Esmann, M. (1992) · Journal of Bioenergetics and Biomembranes · doi:10.1007/bf00768846 · Cited by 563
Burst Firing in Dopamine Neurons Induced by N -Methyl-D-aspartate: Role of Electrogenic Sodium Pump
Johnson, S. W., Seutin, V., & North, R. A. (1992) · Science · doi:10.1126/science.1329209 · Cited by 419
Metadata
- Authors
- Weer, P. D., Gadsby, D. C., & Rakowski, R. F.
- Venue
- Annual Review of Physiology
- Publisher
- Annual Reviews
- Published
- 1988-10
- Volume
- 50
- Issue
- 1
- Pages
- 225-241
- ISSN
- 0066-4278 (ISSN-L)
- 1545-1585
- OpenAlex
- W2106274893
- Cited by
- 192
- References
- 0
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voltage Dependence of the Na-K Pump. https://app.cochat.ai/papers/10.1146/annurev.ph.50.030188.001301
- The paper
- Weer, P. D., Gadsby, D. C., & Rakowski, R. F. (1988). Voltage Dependence of the Na-K Pump. Annual Review of Physiology. https://doi.org/10.1146/annurev.ph.50.030188.001301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.