CoChat

Lymphangiograms: Their Diagnostic and Therapeutic Potential

Wallace, Sidney, Jackson, Laird, Schaffer, Burton, Gould, John, Greening, Roy R., Weiss, Arthur, Kramer, Simon · 1961 · Radiology
Cited by 166

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Lymphangiography, the radiographic demonstration of the lymphatic system by intralymphatic injection of contrast material, has opened a new field of investigation. Earlier attempts at indirect lymphography were made by injection of radiopaque material into the subcutaneous tissue with uptake in the adjacent nodes (1). Direct injection into large palpable nodes, lymphadenography, was introduced by Carvalho in 1931 (6, 26, 31). Kinmonth in 1955 developed lymphangiography as a method of study of lymphedema of the lower extremities (20). Hreshchyshyn and Sheehan recently modified this approach (13). We have utilized the procedure with only minor variations to study the dynamics of the lymphatic system and the abnormalities in the nodes in various disease states. We have correlated our findings in man with those of animal investigations as summarized by Drinker, Yoffey, and Courtice (8, 29). Our investigation was initiated at Jefferson Medical College Hospital and later extended to include the group at Philadelphia General Hospital. Method The method of lymphangiography to be described here applies to both the upper and lower extremities. Half a milliliter (0.5 ml.) of a mixture containing equal parts of 0.5 per cent Evans blue dye and 1 per cent procaine hydrochloride is injected intradermally into the interdigital web space between the first and second or fourth and fifth digits of the extremity. The procaine hydrochloride is added to minimize the transitory pain which occurs when the dye is injected alone. The blue dye is selectively absorbed by the lymphatics, making them readily identifiable within fifteen to thirty minutes (Fig. 1). At that time, with aseptic technic, a small skin incision is made proximal to the injection site and a lymphatic conveying the blue dye is identified and isolated. An untied ligature is placed around the vessel proximally to obstruct and distend it temporarily (Fig. 2). A small, narrow-gauge needle (25 to 30 depending on lymphatic size), which has previously been fitted to a polyethylene tube, is then threaded into the vessel and secured in place by a ligature. Ethiodol, an ethyl ester of poppyseed oil containing 37 per cent iodine, is placed in a syringe connected by an adapter to the polyethylene tubing, and low and constant pressure is applied to the syringe by means of a “C-clamp” apparatus, which is manually driven (Fig. 3). The contrast material is thus slowly forced into the lymphatic system. Best and most extensive visualization is achieved when injections are prolonged over a period of an hour and a half to two hours, at a rate of approximately 7 ml. per hour. Undue pressure may cause extravasation of the contrast material into the soft tissues of the extremity. We generally use 5 to 7 ml. of radiopaque material in the upper extremity and 10 to 15 ml. in the lower extremity, not exceeding a total of 25 ml. if both legs are injected.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/76.2.179

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 166

Metadata

Authors
Wallace, S., Jackson, L., Schaffer, B., Gould, J., Greening, R. R., Weiss, A., & Kramer, S.
Venue
Radiology
Published
1961-02
Volume
76
Issue
2
Pages
179-199
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1985654994
Cited by
166
References
1
FWCI
36.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.