CoChat

Automated Computer Analysis of Radiographic Images

Meyers, Phillip H., Nice, Charles M., Becker, Hal C., Nettleton, Wilson J., Sweeney, James W., Meckstroth, George R. · 1964 · Radiology
Cited by 101

The DOI matches its Crossref record.

Abstract

Lee B. Lusted in his Memorial Fund Lecture (1) anticipated the device: “an electronic ‘scanner-computer’ to look at chest photofluorograms and to separate the clearly normal chest films from the abnormal chest films. The abnormal chest films would be marked for later study by the radiologist.” This automated computer analysis concept was based on some preliminary studies by Pendergrass and Tolles who showed that automatic scanning of photofluorograms could produce satisfactory density tracings. We are now reporting a method of automated computer analysis of radiographic images utilizing algorithms (a rule of procedure for solving a recurrent mathematical or logical problem) for recognizing parts of the radiographic image. Method and Results Thirty-seven 70 mm. photofluorograms were digitized and put on magnetic tape, using an improved image-scanning system similar to one previously reported (2). The radiographic image of the chest on magnetic tape contains 502 digit samples per line times 320 horizontal scan lines for a total of 160,000 two-digit samples per 70 mm photofluorogram of the chest. The computer then processes the digital image by integrating each of its vertical columns on the IBM 1410 computer and writes out one record on magnetic tape for each of the input image matrices. The radiograph is now represented on magnetic tape by a single record containing 500 samples. With another program the computer can print out a plotted curve analogous to an electrocardiogram tracing, which represents the radiograph. (Figure 1 depicts an integrated strip chart of a 70 mm photofluorogram of the chest.) The magnetic “summed tapes” which have the integrated vertical columns of each radiograph are then used as an input for the stored program containing the algorithm. Eight indices are determined and automatically printed as follows: Address of left rib peak (LRP) Address of left edge of heart (LEH) Address of maximum value in heart band (MVH) Address of right edge of heart (REH) Address of right rib peak (RRP) Maximum transverse diameter of the heart (MDH) Maximum transverse diameter of the thorax (MDT) Cardiothoracic ratio (MDH/MDT = CR) (4) (Fig. 5). Figures 2 and 3 are condensed flow charts of the data through the programs. Tables IA and IB show the cardiothoracic ratios computed and measured with per cent differences between these values. Discussion For the detailed analysis of the programming and electronics involved, the reader is referred to other work by our group (2). The results of the automated comouter analysis of the cardiothoracic ratios are summarized in Tables IA and IB. Table IA shows the cardiothoracic ratios as measured by four investigators: (a) an American Board certified radiologist; (b) a resident in radiology; (c) a computer scientist; and (d) a biomedical engineer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/83.6.1029

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 101

Metadata

Authors
Meyers, P. H., Nice, C. M., Becker, H. C., Nettleton, W. J., Sweeney, J. W., & Meckstroth, G. R.
Venue
Radiology
Published
1964-12
Volume
83
Issue
6
Pages
1029-1034
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2077375822
Cited by
101
References
0
FWCI
2.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated Computer Analysis of Radiographic Images. https://app.cochat.ai/papers/10.1148/83.6.1029
The paper
Meyers, P. H., Nice, C. M., Becker, H. C., Nettleton, W. J., Sweeney, J. W., & Meckstroth, G. R. (1964). Automated Computer Analysis of Radiographic Images. Radiology. https://doi.org/10.1148/83.6.1029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.