The DOI matches its Crossref record.
Three-dimensional Volume Rendering of Spiral CT Data: Theory and Method
Abstract
Three-dimensional (3D) medical images of computed tomographic (CT) data sets can be generated with a variety of computer algorithms. The three most commonly used techniques are shaded surface display, maximum intensity projection, and, more recently, 3D volume rendering. Implementation of 3D volume rendering involves volume data management, which relates to operations including acquisition, resampling, and editing of the data set; rendering parameters including window width and level, opacity, brightness, and percentage classification; and image display, which comprises techniques such as "fly-through" and "fly-around," multiple-view display, obscured structure and shading depth cues, and kinetic and stereo depth cues. An understanding of both the theory and method of 3D volume rendering is essential for accurate evaluation of the resulting images. Three-dimensional volume rendering is useful in a wide variety of applications but is just now being incorporated into commercially available software packages for medical imaging. Although further research is needed to determine the efficacy of 3D volume rendering in clinical applications, with wider availability and improved cost-to-performance ratios in computing, 3D volume rendering is likely to enjoy widespread acceptance in the medical community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Limkin, E. J., Sun, R., Dercle, L., Zacharaki, E. I., Robert, C., Reuzé, S., Schernberg, A., Paragios, N., Deutsch, E., & Ferté, C. (2017) · Annals of Oncology · doi:10.1093/annonc/mdx034 · Cited by 757
Kirkpatrick, I. D. C., Kroeker, M. A., & Greenberg, H. M. (2003) · Radiology · doi:10.1148/radiol.2291020991 · Cited by 365
Schwartzman, D., Lacomis, J., & Wigginton, W. G. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00124-4 · Cited by 262
Automated lung segmentation for thoracic CT
Armato, S. G., & Sensakovic, W. F. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.06.005 · Cited by 259
Metadata
- Authors
- Calhoun, P. S., Kuszyk, B. S., Heath, D. G., Carley, J. C., & Fishman, E. K.
- Venue
- RadioGraphics
- Published
- 1999-05
- Volume
- 19
- Issue
- 3
- Pages
- 745-764
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2140441287
- Cited by
- 550
- References
- 0
- FWCI
- 38.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional Volume Rendering of Spiral CT Data: Theory and Method. https://app.cochat.ai/papers/10.1148/radiographics.19.3.g99ma14745
- The paper
- Calhoun, P. S., Kuszyk, B. S., Heath, D. G., Carley, J. C., & Fishman, E. K. (1999). Three-dimensional Volume Rendering of Spiral CT Data: Theory and Method. RadioGraphics. https://doi.org/10.1148/radiographics.19.3.g99ma14745
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.