Fluoroscopy: Patient Radiation Exposure Issues
Abstract
Fluoroscopic procedures (particularly prolonged interventional procedures) may involve high patient radiation doses. The radiation dose depends on the type of examination, the patient size, the equipment, the technique, and many other factors. The performance of the fluoroscopy system with respect to radiation dose is best characterized by the receptor entrance exposure and skin entrance exposure rates, which should be assessed at regular intervals. Management of patient exposure involves not only measurement of these rates but also clinical monitoring of patient doses. Direct monitoring of patient skin doses during procedures is highly desirable, but current methods still have serious limitations. Skin doses may be reduced by using intermittent exposures, grid removal, last image hold, dose spreading, beam filtration, pulsed fluoroscopy, and other dose reduction techniques. Proper training of fluoroscopic operators, understanding the factors that influence radiation dose, and use of various dose reduction techniques may allow effective management of patient dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vañó, E., González, L., Beneytez, F., & Moreno, F. (1998) · The British Journal of Radiology · doi:10.1259/bjr.71.847.9771383 · Cited by 261
Perceptual comparison of pulsed and continuous fluoroscopy
Aufrichtig, R., Xue, P., Thomas, C. W., Gilmore, G. C., & Wilson, D. L. (1994) · Medical Physics · doi:10.1118/1.597285 · Cited by 131
ROSENTHAL, L. S., Mahesh, M., Beck, T., Saul, J. P., Miller, J. M., Kay, N., Klein, L. S., Huang, S., Gillette, P., Prystowsky, E. N., et al. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00356-7 · Cited by 130
Self-citationROSENTHAL, L. S., Beck, T., Williams, J., Mahesh, M., Herman, M., DINERMAN, J. L., CALKINS, H., & Lawrence, J. H. (1997) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1997.tb03574.x · Cited by 80
Self-citationStandardized Methods for Measuring Diagnostic X-Ray Exposures
Chu, R. Y. L., Fisher, J., Archer, B. R., Conway, B. J., Goodsitt, M. M., Glaze, S. A., Gray, J. E., & Strauss, K. J. (1990) · doi:10.37206/30 · Cited by 76
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Metadata
- Authors
- Mahesh, M.
- Venue
- RadioGraphics
- Published
- 2001-07
- Volume
- 21
- Issue
- 4
- Pages
- 1033-1045
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2165259839
- Cited by
- 410
- References
- 5
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluoroscopy: Patient Radiation Exposure Issues. https://app.cochat.ai/papers/10.1148/radiographics.21.4.g01jl271033
- The paper
- Mahesh, M. (2001). Fluoroscopy: Patient Radiation Exposure Issues. RadioGraphics. https://doi.org/10.1148/radiographics.21.4.g01jl271033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.