Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Mesenteric Venous Thrombosis: Diagnosis and Noninvasive Imaging

Bradbury, Michelle S., Kavanagh, Peter V., Bechtold, Robert E., Chen, Michael Y., Ott, David J., Regan, John D., Weber, Therese M. · 2002 · RadioGraphics

Abstract

Mesenteric venous thrombosis is an uncommon but potentially lethal cause of bowel ischemia. Several imaging methods are available for diagnosis, each of which has advantages and disadvantages. Doppler ultrasonography allows direct evaluation of the mesenteric and portal veins, provides semiquantitative flow information, and allows Doppler waveform analysis of the visceral vessels; however, it is operator dependent and is often limited by overlying bowel gas. Conventional contrast material-enhanced computed tomography (CT) allows sensitive detection of venous thrombosis within the central large vessels of the portomesenteric circulation and any associated secondary findings; however, it is limited by respiratory misregistration, motion artifact, and substantially decreased longitudinal spatial resolution. Helical CT and CT angiography, especially when performed with multi-detector row scanners, and magnetic resonance (MR) imaging, particularly gadolinium-enhanced MR angiography, enable volumetric acquisitions in a single breath hold, eliminating motion artifact and suppressing respiratory misregistration. Helical CT angiography and three-dimensional gadolinium-enhanced MR angiography should be considered the primary diagnostic modalities for patients with a high clinical suspicion of mesenteric ischemia. Conventional angiography is reserved for equivocal cases at noninvasive imaging and is also used in conjunction with transcatheter therapeutic techniques in management of symptomatic portal and mesenteric venous thrombosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiographics.22.3.g02ma10527

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 210

Metadata

Authors
Bradbury, M. S., Kavanagh, P. V., Bechtold, R. E., Chen, M. Y., Ott, D. J., Regan, J. D., & Weber, T. M.
Venue
RadioGraphics
Published
2002-05
Volume
22
Issue
3
Pages
527-541
ISSN
  • 0271-5333 (ISSN-L)
  • 1527-1323
OpenAlex
W2141999403
Cited by
210
References
1
FWCI
6.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mesenteric Venous Thrombosis: Diagnosis and Noninvasive Imaging. https://app.cochat.ai/papers/10.1148/radiographics.22.3.g02ma10527
The paper
Bradbury, M. S., Kavanagh, P. V., Bechtold, R. E., Chen, M. Y., Ott, D. J., Regan, J. D., & Weber, T. M. (2002). Mesenteric Venous Thrombosis: Diagnosis and Noninvasive Imaging. RadioGraphics. https://doi.org/10.1148/radiographics.22.3.g02ma10527

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.