Computer-aided Classification of Breast Masses: Performance and Interobserver Variability of Expert Radiologists versus Residents
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate the interobserver variability in descriptions of breast masses by dedicated breast imagers and radiology residents and determine how any differences in lesion description affect the performance of a computer-aided diagnosis (CAD) computer classification system. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant study, and the requirement to obtain informed consent was waived. Images of 50 breast lesions were individually interpreted by seven dedicated breast imagers and 10 radiology residents, yielding 850 lesion interpretations. Lesions were described with use of 11 descriptors from the Breast Imaging Reporting and Data System, and interobserver variability was calculated with the Cohen κ statistic. Those 11 features were selected, along with patient age, and merged together by a linear discriminant analysis (LDA) classification model trained by using 1005 previously existing cases. Variability in the recommendations of the computer model for different observers was also calculated with the Cohen κ statistic. RESULTS: A significant difference was observed for six lesion features, and radiology residents had greater interobserver variability in their selection of five of the six features than did dedicated breast imagers. The LDA model accurately classified lesions for both sets of observers (area under the receiver operating characteristic curve = 0.94 for residents and 0.96 for dedicated imagers). Sensitivity was maintained at 100% for residents and improved from 98% to 100% for dedicated breast imagers. For residents, the computer model could potentially improve the specificity from 20% to 40% (P < .01) and the κ value from 0.09 to 0.53 (P < .001). For dedicated breast imagers, the computer model could increase the specificity from 34% to 43% (P = .16) and the κ value from 0.21 to 0.61 (P < .001). CONCLUSION: Among findings showing a significant difference, there was greater interobserver variability in lesion descriptions among residents; however, an LDA model using data from either dedicated breast imagers or residents yielded a consistently high performance in the differentiation of benign from malignant breast lesions, demonstrating potential for improving specificity and decreasing interobserver variability in biopsy recommendations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cheng, J.-Z., Ni, D., Chou, Y.-H., Qin, J., Tiu, C.-M., Chang, Y.-C., Huang, C.-S., Shen, D., & Chen, C.-M. (2016) · Scientific Reports · doi:10.1038/srep24454 · Cited by 755
Yu-Jen Chen, Y.-J., Hua, K.-L., Hsu, C.-H., Cheng, W.-H., & Hidayati, S. C. (2015) · OncoTargets and Therapy · doi:10.2147/ott.s80733 · Cited by 542
Dalmiş, M. U., Gubern-Mérida, A., Vreemann, S., Bult, P., Karssemeijer, N., Mann, R., & Teuwen, J. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000544 · Cited by 120
Choi, J. S., Han, B.-K., Ko, E. S., Bae, J. M., Ko, E. Y., Song, S. H., Kwon, M.-R., Shin, J. H., & Hahn, S. Y. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0530 · Cited by 104
Metadata
- Authors
- Singh, S., Maxwell, J., Baker, J. A., Nicholas, J. L., & Lo, J. Y.
- Venue
- Radiology
- Published
- 2011-01
- Volume
- 258
- Issue
- 1
- Pages
- 73-80
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2034041856
- Cited by
- 49
- References
- 0
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer-aided Classification of Breast Masses: Performance and Interobserver Variability of Expert Radiologists versus Residents. https://app.cochat.ai/papers/10.1148/radiol.10081308
- The paper
- Singh, S., Maxwell, J., Baker, J. A., Nicholas, J. L., & Lo, J. Y. (2011). Computer-aided Classification of Breast Masses: Performance and Interobserver Variability of Expert Radiologists versus Residents. Radiology. https://doi.org/10.1148/radiol.10081308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.