The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Advanced Hepatic Ablation Technique for Creating Complete Cell Death: Irreversible Electroporation
Abstract
PURPOSE: To evaluate the effectiveness of irreversible electroporation (IRE) in hepatic tissue ablation and the radiologic-pathologic correlation of IRE-induced cell death. MATERIALS AND METHODS: On approval of the animal research committee, 16 Yorkshire pigs underwent ultrasonography (US)-guided IRE of normal liver. A total of 55 ablation zones were created, which were imaged with US, magnetic resonance (MR) imaging, and computed tomography (CT) and evaluated with immunohistochemical analysis, including hematoxylin-eosin (H-E), Von Kossa, and von Willibrand factor (vWF) staining and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay. RESULTS: At gross section examination, the mean diameter of the ablation zones was 33.5 mm + or - 3.0 (standard deviation) and was achieved in 6.9 minutes (mean total procedure time per ablation), with a mean difference of 2.5 mm + or - 3.6 between US and gross section measurements (r = 0.804). No complications were seen in any of the 16 animals. IRE ablation zones were well characterized with US, CT, and MR imaging, and real-time monitoring was feasible with US. H-E, Von Kossa, and vWF staining showed complete cell death, with a sharply demarcated treatment area. Bile ducts and vessels were completely preserved. Areas of complete cell death were stained positive for apoptotic markers (TUNEL, BCL-2 oncoprotein), suggesting involvement of the apoptotic process in the pathophysiology of cell death caused by IRE. CONCLUSION: In an animal model, IRE proved to be a fast, safe, and potent ablative method, causing complete tissue death by means of apoptosis. Cell death is seen with full preservation of periablative zone structures, including blood vessels, bile ducts, and neighboring nonablated tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Hepatogastroenterology · doi:10.5754/hge12281 · Cited by 2,097
Morphologic and biochemical hallmarks of apoptosis
Saraste, A. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(99)00384-3 · Cited by 1,466
Livraghi, T., Solbiati, L., Meloni, M. F., Gazelle, G. S., Halpern, E. F., & Goldberg, S. N. (2003) · Radiology · doi:10.1148/radiol.2262012198 · Cited by 1,298
Tissue Ablation with Irreversible Electroporation
Davalos, R. V., Mir, L. M., & Rubinsky, B. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8981-8 · Cited by 1,293
In Vivo Results of a New Focal Tissue Ablation Technique: Irreversible Electroporation
Edd, J. F., Horowitz, L., Davalos, R. V., Mir, L. M., & Rubinsky, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873745 · Cited by 510
Irreversible Electroporation in Medicine
Rubinsky, B. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600401 · Cited by 415
Livraghi, T., Solbiati, L., Meloni, F., Ierace, T., Goldberg, S. N., & Gazelle, G. S. (2003) · Cancer · doi:10.1002/cncr.11426 · Cited by 329
Cancer Cells Ablation with Irreversible Electroporation
Miller, L., Leor, J., & Rubinsky, B. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400615 · Cited by 298
Oshowo, A., Gillams, A., Harrison, E., Lees, W. R., & Taylor, I. (2003) · British Journal of Surgery · doi:10.1002/bjs.4264 · Cited by 279
Lee, E. W., Loh, C. T., & Kee, S. T. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600404 · Cited by 241
Self-citationLencioni, R., Crocetti, L., Cioni, D., Della Pina, C., & Bartolozzi, C. (2004) · Investigative Radiology · doi:10.1097/00004424-200411000-00007 · Cited by 169
Carey, R. I., & Leveillee, R. J. (2007) · Journal of Endourology · doi:10.1089/end.2007.9943 · Cited by 67
Ultrasound Monitoring of In Vitro Radio Frequency Ablation by Echo Decorrelation Imaging
Mast, T. D., Pucke, D. P., Subramanian, S., et al. (2008) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2008.27.12.1685 · Cited by 62
Cited by
Electroporation-Based Technologies for Medicine: Principles, Applications, and Challenges
Yarmush, M. L., Golberg, A., Serša, G., Kotnik, T., & Miklavčič, D. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104622 · Cited by 889
Cell death due to electroporation – A review
Batista Napotnik, T., Polajžer, T., & Miklavčič, D. (2021) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2021.107871 · Cited by 542
Scheffer, H. J., Nielsen, K., de Jong, M. C., van Tilborg, A. A. J. M., Vieveen, J. M., Bouwman, A. (. A. )., Meijer, S., van Kuijk, C., van den Tol, P. (. P. )., & Meijerink, M. R. (2014) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2014.01.028 · Cited by 421
Tumor Ablation: Common Modalities and General Practices
Knavel, E. M., & Brace, C. L. (2013) · Techniques in Vascular and Interventional Radiology · doi:10.1053/j.tvir.2013.08.002 · Cited by 368
Cannon, R., Ellis, S., Hayes, D., Narayanan, G., & Martin, R. C. G. (2013) · Journal of Surgical Oncology · doi:10.1002/jso.23280 · Cited by 338
Metadata
- Authors
- Lee, E. W., Chen, C., Prieto, V. E., Dry, S. M., Loh, C. T., & Kee, S. T.
- Venue
- Radiology
- Published
- 2010-05
- Volume
- 255
- Issue
- 2
- Pages
- 426-433
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2146135137
- Cited by
- 330
- References
- 13
- FWCI
- 18.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.