Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Evaluation of Dual-Energy CT for Differentiating Intracerebral Hemorrhage from Iodinated Contrast Material Staining

Gupta, Rajiv, Phan, Catherine M., Leidecker, Christianne, Brady, Thomas J., Hirsch, Joshua A., Nogueira, Raul G., Yoo, Albert J.·2010·Radiology

Abstract

PURPOSE: To evaluate the efficacy of dual-energy computed tomography (CT) in the differentiation of intracerebral hemorrhage (ICH) from iodinated contrast material in patients who received contrast material via intraarterial or intravenous delivery. MATERIALS AND METHODS: This retrospective study was approved by the local institutional review board, which waived the informed consent requirement for the analysis. Sixteen patients with acute stroke and two with head trauma who had undergone intraarterial or intravenous administration of iodinated contrast material were evaluated by using dual-energy CT to differentiate areas of hyperattenuation secondary to contrast material staining from those representing ICH. A dual-energy CT scanner was used for imaging at 80 and 140 kV, and a three-material decomposition algorithm was used to obtain virtual unenhanced images and iodine overlay images. The sensitivity, specificity, and accuracy of dual-energy CT in the prospective differentiation of intraparenchymal contrast material from hemorrhage were obtained. Follow-up images were used as the standard of reference. RESULTS: There were 28 intraparenchymal areas of hyperattenuation classified at dual-energy CT as iodinated contrast material staining (n = 20, 71%), hemorrhage (n = 5, 18%), or both (n = 3, 11%). Two of the three areas of hyperattenuation seen on both virtual unenhanced and iodine overlay images were related to mineralization. The sensitivity, specificity, and accuracy of dual-energy CT in the identification of hemorrhage were 100% (six of six areas), 91% (20 of 22 areas), and 93% (26 of 28 areas), respectively. CONCLUSION: Dual-energy CT can help differentiate ICH from iodinated contrast material staining with high sensitivity and specificity in patients who have recently received intraarterial or intravenous iodinated contrast material.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.10091806

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 250

Metadata

Authors
Gupta, R., Phan, C. M., Leidecker, C., Brady, T. J., Hirsch, J. A., Nogueira, R. G., & Yoo, A. J.
Venue
Radiology
Published
2010-10
Volume
257
Issue
1
Pages
205-211
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1987631989
Cited by
250
References
2
FWCI
5.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Dual-Energy CT for Differentiating Intracerebral Hemorrhage from Iodinated Contrast Material Staining. https://app.cochat.ai/papers/10.1148/radiol.10091806
The paper
Gupta, R., Phan, C. M., Leidecker, C., Brady, T. J., Hirsch, J. A., Nogueira, R. G., & Yoo, A. J. (2010). Evaluation of Dual-Energy CT for Differentiating Intracerebral Hemorrhage from Iodinated Contrast Material Staining. Radiology. https://doi.org/10.1148/radiol.10091806

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.