Tetralogy of Fallot: 3D Velocity-encoded MR Imaging for Evaluation of Right Ventricular Valve Flow and Diastolic Function in Patients after Correction
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate three-dimensional (3D) velocity-encoded (VE) magnetic resonance (MR) imaging, as compared with two-dimensional (2D) VE MR imaging, for assessment of pulmonary valve (PV) and tricuspid valve (TV) flow, with planimetry as the reference standard, and to evaluate diastolic function in patients with a corrected tetralogy of Fallot (TOF). MATERIALS AND METHODS: Local institutional review board approval was obtained, and patients or their parents gave informed consent. Twenty-five patients with a corrected TOF (12 male, 13 female; mean age, 13.1 years +/- 2.7 [standard deviation]; age range, 8-18 years) and 19 control subjects (12 male, seven female; mean age, 14.1 years +/- 2.4; age range, 8-18 years) underwent planimetric MR imaging, 2D VE MR imaging, and 3D VE MR imaging for TV and PV flow evaluation. For evaluation of diastolic function, PV and TV flow were summated. Data were analyzed by using linear regression analysis, paired and unpaired t testing, and Bland-Altman plots. RESULTS: Strong correlations between the 2D VE MR and 3D VE MR measurements of PV flow (for forward flow: r = 0.87, P < .01; for backward flow: r = 0.97, P < .01) were observed. With PV effective flow as a reference, 3D TV effective flow measurements were more accurate than 2D TV effective flow measurements: In patients, the mean 2D TV effective flow versus 2D PV effective flow difference was 17.6 mL +/- 11 (P < .001), and the mean 3D TV effective flow versus 3D PV effective flow difference was -1.2 mL +/- 4.7 (P = .22). Diastolic functional impairment in patients could be detected at 3D VE MR imaging diastolic assessment. CONCLUSION: Three-dimensional VE MR imaging is accurate for PV flow assessment and is more accurate than 2D VE MR imaging for TV flow evaluation. Assessment of diastolic function with 3D VE MR imaging can facilitate ongoing research of diastolic dysfunction in patients with a corrected TOF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Gatzoulis, M. A., Balaji, S., Webber, S. A., Siu, S. C., Hokanson, J. S., Poile, C., Rosenthal, M., Nakazawa, M., Moller, J. H., Gillette, P. C., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02714-8 · Cited by 1,779
Cited by
Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation
Zoghbi, W. A., Adams, D., Bonow, R. O., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Hahn, R. T., Han, Y., Hung, J., Lang, R. M., et al. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.01.007 · Cited by 3,556
Geva, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-9 · Cited by 582
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Valente, A. M., Cook, S., Festa, P., Ko, H. H., Krishnamurthy, R., Taylor, A. M., Warnes, C. A., Kreutzer, J., & Geva, T. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.11.009 · Cited by 317
Early Feasibility Study of a Transcatheter Tricuspid Valve Annuloplasty
Hahn, R. T., Meduri, C. U., Davidson, C. J., Lim, S., Nazif, T. M., Ricciardi, M. J., Rajagopal, V., Ailawadi, G., Vannan, M. A., Thomas, J. D., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.01.054 · Cited by 281
4D-Flow MRI Characterization of Pulmonary Flow in Repaired Tetralogy of Fallot
Hudani, A., Ihsan Ali, S., Patton, D., Myers, K. A., Fine, N. M., White, J. A., Greenway, S., & Garcia, J. (2023) · Applied Sciences · doi:10.3390/app13052810 · Cited by 9
Metadata
- Authors
- van der Hulst, A. E., Westenberg, J. J. M., Kroft, L. J. M., Bax, J. J., Blom, N. A., de Roos, A., & Roest, A. A. W.
- Venue
- Radiology
- Published
- 2010-09
- Volume
- 256
- Issue
- 3
- Pages
- 724-734
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2118197756
- Cited by
- 59
- References
- 3
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.