The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Characterization of Complex Adnexal Masses: Value of Adding Perfusion- and Diffusion-weighted MR Imaging to Conventional MR Imaging
Abstract
PURPOSE: To retrospectively determine the value of adding perfusion-weighted (PW) and diffusion-weighted (DW) sequences to a conventional magnetic resonance (MR) imaging protocol to differentiate benign from malignant tumors. MATERIALS AND METHODS: The institutional ethics committee approved this retrospective study and waived the requirement to obtain informed consent. MR images in 87 women (age range, 25-87 years) who underwent imaging before surgery for complex adnexal masses-excluding endometriomas and cystic teratomas-were analyzed. Conventional morphologic, perfusion, and diffusion MR criteria of malignancy were recorded. Three independent observers reviewed images in four steps: conventional MR images alone, conventional MR images and PW images combined, conventional MR images and DW images combined, and conventional, PW, and DW MR images combined. Receiver operating characteristic curve analysis was performed to compare the results of the readings. A recursive partitioning model was built to establish a multivariate decision tree. RESULTS: There was almost perfect agreement for lesion characterization regardless of the reader experiment or step considered (κ = 0.811-0.929). Area under the receiver operating characteristic curve values were higher for conventional and DW images combined, conventional and PW images combined, and conventional, DW, and PW images combined compared with conventional MR images alone (P < .05). For all readers, the accuracy of conventional, PW, and DW imaging combined was higher than that of conventional MR imaging alone for benign masses (P < .01) but not for malignant masses (P = .24). The addition of both PW and DW images led to a correct change in the diagnosis in 19% (11 of 57 patients), 23% (13 of 57 patients), and 24% (14 of 57 patients) of cases for readers 1, 2, and 3, respectively, with no incorrect changes. Conventional, PW, and DW MR imaging criteria were combined to generate a decision tree giving an accuracy of 95%. CONCLUSION: The addition of PW and DW sequences to a conventional MR imaging protocol improved the diagnostic accuracy in the characterization of complex adnexal masses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529786 · Cited by 4,332
Invited. Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion‐weighted imaging
Yamashita, Y., Tang, Y., & Takahashi, M. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080216 · Cited by 92
Cited by
Sala, E., Rockall, A. G., Freeman, S. J., Mitchell, D. G., & Reinhold, C. (2013) · Radiology · doi:10.1148/radiol.12120315 · Cited by 347
ESUR recommendations for MR imaging of the sonographically indeterminate adnexal mass: An update
Forstner, R., Thomassin-Naggara, I., Cunha, T. M., Kinkel, K., Masselli, G., Kubik-Huch, R., Spencer, J. A., & Rockall, A. (2017) · European Radiology · doi:10.1007/s00330-016-4600-3 · Cited by 204
Self-citation
Metadata
- Authors
- Thomassin-Naggara, I., Toussaint, I., Perrot, N., Rouzier, R., Cuenod, C. A., Bazot, M., & Daraï, E.
- Venue
- Radiology
- Published
- 2011-03
- Volume
- 258
- Issue
- 3
- Pages
- 793-803
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2126364665
- Cited by
- 195
- References
- 2
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.