The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Differentiation of Small Hepatic Hemangioma from Small Hepatocellular Carcinoma: Recently Introduced Spectral CT Method
Abstract
PURPOSE: To investigate the usefulness of computed tomographic (CT) spectral imaging parameters in differentiating small (≤3 cm) hepatic hemangioma (HH) from small hepatocellular carcinoma (HCC), with or without cirrhosis, during the late arterial phase (AP) and portal venous phase (PVP). MATERIALS AND METHODS: This prospective study was institutional review board approved, and written informed consent was obtained from all patients. The authors examined 49 patients (39 men, 10 women; 65 lesions) with CT spectral imaging during the AP and the PVP. Twenty-one patients had HH; nine, HCC with cirrhosis; and 19, HCC without cirrhosis. Iodine concentrations were derived from iodine-based material-decomposition CT images and normalized to the iodine concentration in the aorta. The difference in iodine concentration between the AP and PVP (ie, iodine concentration difference [ICD]) and the lesion-to-normal parenchyma ratio (LNR) were calculated. Two readers qualitatively assessed lesion types on the basis of conventional CT characteristics. Sensitivity and specificity were compared between the qualitative and quantitative studies. The two-sample t test was performed to compare quantitative parameters between HH and HCC. RESULTS: Normalized iodine concentrations (NICs) and LNRs in patients with HH differed significantly from those in patients with HCC and cirrhosis and those in patients with HCC without cirrhosis: Mean NICs were 0.47 mg/mL ± 0.24 (standard deviation) versus 0.23 mg/mL ± 0.10 and 0.23 mg/mL ± 0.08, respectively, during the AP and 0.83 mg/mL ± 0.38 versus 0.47 mg/mL ± 0.86 and 0.52 mg/mL ± 0.11, respectively, during the PVP. Mean LNRs were 5.87 ± 3.36 versus 2.56 ± 1.10 and 2.29 ± 0.87, respectively, during the AP and 2.01 ± 1.33 versus 0.96 ± 0.16 and 0.93 ± 0.26, respectively, during the PVP. The mean ICD for the HH group (1.37 mg/mL ± 0.84) was significantly higher than the mean ICDs for the HCC-cirrhosis (0.33 mg/mL ± 0.29) (P < .001) and HCC-no cirrhosis (0.82 mg/mL ± 0.99) (P = .03) groups. The combination of NIC and LNR had higher sensitivity and specificity compared with those of conventional qualitative CT image analysis during individual and combined phases. CONCLUSION: Use of spectral CT with fast tube voltage switching may increase the sensitivity for differentiating small hemangiomas from small HCCs in two-phase scanning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical anatomy and anatomical surgery of the liver
Bismuth, H. (1982) · World Journal of Surgery · doi:10.1007/bf01656368 · Cited by 791
Cited by
State of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
Metadata
- Authors
- Lv, P., Lin, X. Z., Li, J., Li, W., & Chen, K.
- Venue
- Radiology
- Published
- 2011-06
- Volume
- 259
- Issue
- 3
- Pages
- 720-729
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1965510293
- Cited by
- 205
- References
- 1
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differentiation of Small Hepatic Hemangioma from Small Hepatocellular Carcinoma: Recently Introduced Spectral CT Method. https://app.cochat.ai/papers/10.1148/radiol.11101425
- The paper
- Lv, P., Lin, X. Z., Li, J., Li, W., & Chen, K. (2011). Differentiation of Small Hepatic Hemangioma from Small Hepatocellular Carcinoma: Recently Introduced Spectral CT Method. Radiology. https://doi.org/10.1148/radiol.11101425
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.