Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record.

Diagnostic Performance of Gray-Scale US and Elastography in Solid Thyroid Nodules

Moon, Hee Jung, Sung, Ji Min, Kim, Eun-Kyung, Yoon, Jung Hyun, Youk, Ji Hyun, Kwak, Jin Young·2012·Radiology

Abstract

PURPOSE: To evaluate the diagnostic performance of gray-scale ultrasonography (US) and elastography in differentiating benign and malignant thyroid nodules. MATERIALS AND METHODS: This was an institutional review board-approved retrospective study with waiver of informed consent. A total of 703 solid thyroid nodules in 676 patients (mean age, 49.7 years; range, 18-79 years) were included; there were 556 women (mean age, 49.5 years; range, 20-74 years) and 120 men (mean age, 50.7 years; range, 18-79 years). Nodules with marked hypoechogenicity, poorly defined margins, microcalcifications, and a taller-than-wide shape were classified as suspicious at grayscale US. Findings at elastography were classified according to the Rago criteria and the Asteria criteria. The diagnostic performances of gray-scale US and elastography were compared. For comparison between the diagnostic performances of gray-scale US and the combination of gray-scale US and elastography, three sets of criteria were assigned: criteria set 1, nodules with any suspicious grayscale US feature were assessed as suspicious; criteria set 2, Rago criteria were added as suspicious features to criteria set 1; and criteria set 3, Asteria criteria were added as suspicious features to criteria set 1. The diagnostic performances of gray-scale US, elastography with Rago criteria, and elastography with Asteria criteria, and odds ratios (ORs) with 95% confidence intervals for predicting thyroid malignancy were compared using generalized estimating equation analysis. RESULTS: Of 703 nodules, 217 were malignant and 486 were benign. Sensitivity, negative predictive value (NPV), and OR of gray-scale US for the 703 nodules were 91.7%, 94.7%, and 22.1, respectively, and these values were higher than the 15.7% and 65.4% sensitivity, 71.7% and 79.1% NPV, and 3.7 and 2.6 ORs found for elastography with Rago and Asteria criteria, respectively. Specificity, positive predictive value, and accuracy for criteria set 1 were significantly higher than those for criteria sets 2 and 3 for most of the nodule subgroups that were considered. CONCLUSION: Elastography alone, as well as the combination of elastography and gray-scale US, showed inferior performance in the differentiation of malignant and benign thyroid nodules compared with gray-scale US features; elastography was not a useful tool in recommending fine-needle aspiration biopsy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.11110839

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 251

Metadata

Authors
Moon, H. J., Sung, J. M., Kim, E.-K., Yoon, J. H., Youk, J. H., & Kwak, J. Y.
Venue
Radiology
Published
2012-03
Volume
262
Issue
3
Pages
1002-1013
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2128817896
Cited by
251
References
0
FWCI
21.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Performance of Gray-Scale US and Elastography in Solid Thyroid Nodules. https://app.cochat.ai/papers/10.1148/radiol.11110839
The paper
Moon, H. J., Sung, J. M., Kim, E.-K., Yoon, J. H., Youk, J. H., & Kwak, J. Y. (2012). Diagnostic Performance of Gray-Scale US and Elastography in Solid Thyroid Nodules. Radiology. https://doi.org/10.1148/radiol.11110839

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.