Evaluation of Depth of Myometrial Invasion and Overall Staging in Endometrial Cancer: Comparison of Diffusion-weighted and Dynamic Contrast-enhanced MR Imaging

Beddy, Peter, Moyle, Penelope, Kataoka, Masako, Yamamoto, Adam K., Joubert, Ilse, Lomas, David, Crawford, Robin, Sala, Evis · 2012 · Radiology

Abstract

PURPOSE: To compare the diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging with that of dynamic contrast material-enhanced (DCE) MR imaging in evaluating the depth of myometrial invasion and overall stage in patients with endometrial cancer. MATERIALS AND METHODS: The institutional review board approved this retrospective study; patient consent was not required. From May 2008 to February 2010, 48 women with endometrial cancer underwent preoperative MR imaging, including T1- and T2-weighted imaging, DW MR imaging (b=0 and 800 sec/mm2) and DCE MR imaging. Two radiologists independently interpreted the depth of myometrial invasion, overall stage, and presence of pitfalls associated with inaccurate assessment of myometrial invasion at T1- and T2-weighted imaging, DW MR imaging, and DCE MR imaging. Myometrial invasion and overall stage were compared by using the McNemar test, and κ statistics were used for reader agreement. RESULTS: For assessing the depth of myometrial invasion, diagnostic accuracy, sensitivity, and specificity, respectively, were as follows: DW MR imaging-reader 1, 90%, 84%, and 100%; reader 2, 85%, 84%, and 88%; DCE MR imaging-reader 1, 71%, 61%, and 88%; reader 2, 79%, 77%, and 82%. The improvement in diagnostic accuracy for reader 1 was significant (P=.035). For myometrial invasion, κ values were 0.75 with DW MR imaging and 0.26 with DCE MR imaging. There was no association between inaccurate assessment of myometrial invasion and standard pitfalls with DW MR imaging. Readers 1 and 2 correctly staged more patients by using DW MR imaging (39 and 38 patients, respectively) than by using DCE MR imaging (29 and 30 patients, respectively) (P<.05). For overall stage, κ values were 0.74 with DW MR imaging and 0.22 with DCE MR imaging. CONCLUSION: DW MR imaging has superior diagnostic accuracy in the assessment of myometrial invasion and significantly higher staging accuracy compared with DCE MR imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.11110984

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 190

Metadata

Authors
Beddy, P., Moyle, P., Kataoka, M., Yamamoto, A. K., Joubert, I., Lomas, D., Crawford, R., & Sala, E.
Venue
Radiology
Published
2012-02
Volume
262
Issue
2
Pages
530-537
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2045969043
Cited by
190
References
2
FWCI
8.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Depth of Myometrial Invasion and Overall Staging in Endometrial Cancer: Comparison of Diffusion-weighted and Dynamic Contrast-enhanced MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.11110984
The paper
Beddy, P., Moyle, P., Kataoka, M., Yamamoto, A. K., Joubert, I., Lomas, D., Crawford, R., & Sala, E. (2012). Evaluation of Depth of Myometrial Invasion and Overall Staging in Endometrial Cancer: Comparison of Diffusion-weighted and Dynamic Contrast-enhanced MR Imaging. Radiology. https://doi.org/10.1148/radiol.11110984

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.