Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Readout-segmented Echo-planar Imaging Improves the Diagnostic Performance of Diffusion-weighted MR Breast Examinations at 3.0 T

Bogner, Wolfgang, Pinker-Domenig, Katja, Bickel, Hubert, Chmelik, Marek, Weber, Michael, Helbich, Thomas H., Trattnig, Siegfried, Gruber, Stephan·2012·Radiology

Abstract

PURPOSE: To qualitatively and quantitatively compare the diagnostic value of diffusion-weighted (DW) magnetic resonance (MR) imaging based on standard single-shot echo-planar imaging and readout-segmented echo-planar imaging in patients with breast cancer at 3.0 T. MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained. Forty-seven patients with 49 histopathologically verified lesions were included in this study. In all patients, DW imaging, with single-shot echo-planar imaging and readout-segmented echo-planar imaging with comparable imaging parameters, was performed with a 3.0-T MR imager. Two independent readers visually assessed image quality and lesion conspicuity, and image properties (ie, signal-to-noise ratio, contrast, geometric distortions) were quantified. Regions of interest were drawn in all lesions (28 malignant, 21 benign) and in the normal breast parenchyma to investigate differences in apparent diffusion coefficient (ADC). Diagnostic accuracy was calculated on the basis of an ADC threshold of 1.25 × 10(-3) mm(2)/sec. RESULTS: Each reader found a higher diagnostic accuracy for readout-segmented (96%) than for single-shot (90%) echo-planar imaging. The area under the curve for readout-segmented echo-planar imaging (0.981) was significantly larger than for single-shot echo-planar imaging (0.867) (P = .026). There was no significant difference in the ADC obtained by using either DW imaging method. Lesion conspicuity and image quality of readout-segmented echo-planar imaging were rated superior to those of single-shot echo-planar imaging (P < .001). Readout-segmented echo-planar imaging reduced geometric distortions by a factor of three. CONCLUSION: DW imaging based on readout-segmented echo-planar imaging provided significantly higher image quality and lesion conspicuity than single-shot echo-planar imaging by reducing geometric distortions, image blurring, and artifact level with a clinical high-field-strength MR imager. Thereby, readout-segmented echo-planar imaging reached a higher diagnostic accuracy for the differentiation of benign and malignant breast lesions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12111494

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Bogner, W., Pinker-Domenig, K., Bickel, H., Chmelik, M., Weber, M., Helbich, T. H., Trattnig, S., & Gruber, S.
Venue
Radiology
Published
2012-04
Volume
263
Issue
1
Pages
64-76
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1989309124
Cited by
204
References
2
FWCI
8.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Readout-segmented Echo-planar Imaging Improves the Diagnostic Performance of Diffusion-weighted MR Breast Examinations at 3.0 T. https://app.cochat.ai/papers/10.1148/radiol.12111494
The paper
Bogner, W., Pinker-Domenig, K., Bickel, H., Chmelik, M., Weber, M., Helbich, T. H., Trattnig, S., & Gruber, S. (2012). Readout-segmented Echo-planar Imaging Improves the Diagnostic Performance of Diffusion-weighted MR Breast Examinations at 3.0 T. Radiology. https://doi.org/10.1148/radiol.12111494

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.